SLUSBO6C JANUARY   2014  – October 2018 TPS40425

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
    1.     Device Images
      1. 3.1 Simplified Application Diagram (Dual Output)
  4. Revision History
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 Handling Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Asynchronous Pulse Injection (API)
      2. 7.3.2  Adaptive Voltage Scaling (AVS)
      3. 7.3.3  Switching Frequency and Synchronization
      4. 7.3.4  Voltage Reference
      5. 7.3.5  Output Voltage and Remote Sensing Amplifier
      6. 7.3.6  Current Sensing and Temperature Sensing Modes
        1. 7.3.6.1 Non Smart-Power Operation
        2. 7.3.6.2 Smart-Power Operation.
      7. 7.3.7  Current Sensing
      8. 7.3.8  Temperature Sensing
      9. 7.3.9  Current Sharing
      10. 7.3.10 Linear Regulators
      11. 7.3.11 Power Sequence Between TPS40425 Device and Power Stage
      12. 7.3.12 PWM Signal
        1. 7.3.12.1 PWM Behavior During Soft-start Operation
      13. 7.3.13 Startup and Shutdown
      14. 7.3.14 Pre-Biased Output Start-up
      15. 7.3.15 PGOOD Indication
      16. 7.3.16 Overcurrent Protection
      17. 7.3.17 Overvoltage/Undervoltage Protection
      18. 7.3.18 Overtemperature Fault Protection
      19. 7.3.19 Input Undervoltage Lockout (UVLO)
      20. 7.3.20 Fault Communication
      21. 7.3.21 Fault Protection Summary
    4. 7.4 Device Functional Modes
    5. 7.5 Programming
      1. 7.5.1 Multi-Phase Applications
    6. 7.6 Register Maps
      1. 7.6.1 PMBus General Description
      2. 7.6.2 PMBus Functionality
        1. 7.6.2.1 PMBus Address
        2. 7.6.2.2 PMBus Connections
        3. 7.6.2.3 PMBus Data Format
        4. 7.6.2.4 PMBus Output Voltage Adjustment
          1. 7.6.2.4.1 No Margin Voltage
          2. 7.6.2.4.2 Margin High Voltage State
          3. 7.6.2.4.3 Margin Low State
      3. 7.6.3 Reading the Output Current
      4. 7.6.4 Soft-Start Time
      5. 7.6.5 Turn-On/Turn-Off Delay and Sequencing
    7. 7.7 Supported PMBus Commands
      1. 7.7.1  PAGE (00h)
      2. 7.7.2  OPERATION (01h)
      3. 7.7.3  ON_OFF_CONFIG (02h)
      4. 7.7.4  CLEAR_FAULTS (03h)
      5. 7.7.5  WRITE_PROTECT (10h)
      6. 7.7.6  STORE_USER_ALL (15h)
      7. 7.7.7  RESTORE_USER_ALL (16h)
      8. 7.7.8  CAPABILITY (19h)
      9. 7.7.9  VOUT_MODE (20h)
      10. 7.7.10 VIN_ON (35h)
      11. 7.7.11 VIN_OFF (36h)
      12. 7.7.12 IOUT_CAL_GAIN (38h)
      13. 7.7.13 IOUT_CAL_OFFSET (39h)
      14. 7.7.14 IOUT_OC_FAULT_LIMIT (46h)
      15. 7.7.15 IOUT_OC_FAULT_RESPONSE (47h)
      16. 7.7.16 IOUT_OC_WARN_LIMIT (4Ah)
      17. 7.7.17 OT_FAULT_LIMIT (4Fh)
      18. 7.7.18 OT_WARN_LIMIT (51h)
      19. 7.7.19 TON_RISE (61h)
      20. 7.7.20 STATUS_BYTE (78h)
      21. 7.7.21 STATUS_WORD (79h)
      22. 7.7.22 STATUS_VOUT (7Ah)
      23. 7.7.23 STATUS_IOUT (7Bh)
      24. 7.7.24 STATUS_TEMPERATURE (7Dh)
      25. 7.7.25 STATUS_CML (7Eh)
      26. 7.7.26 STATUS_MFR_SPECIFIC (80h)
      27. 7.7.27 READ_VOUT (8Bh)
      28. 7.7.28 READ_IOUT (8Ch)
      29. 7.7.29 READ_TEMPERATURE_2 (8Eh)
      30. 7.7.30 PMBus_REVISION (98h)
      31. 7.7.31 MFR_SPECIFIC_00 (D0h)
      32. 7.7.32 MFR_SPECIFIC_04 (VREF_TRIM) (D4h)
      33. 7.7.33 MFR_SPECIFIC_05 (STEP_VREF_MARGIN_HIGH) (D5h)
      34. 7.7.34 MFR_SPECIFIC_06 (STEP_VREF_MARGIN_LOW) (D6h)
      35. 7.7.35 MFR_SPECIFIC_07 (PCT_VOUT_FAULT_PG_LIMIT) (D7h)
      36. 7.7.36 MFR_SPECIFIC_08 (SEQUENCE_TON_TOFF_DELAY) (D8h)
      37. 7.7.37 MFR_SPECIFIC_16 (COMM_EEPROM_SPARE) (E0h)
      38. 7.7.38 MFR_SPECIFIC_21 (OPTIONS) (E5h)
      39. 7.7.39 MFR_SPECIFIC_22 (PWM_OSC_SELECT) (E6h)
      40. 7.7.40 MFR_SPECIFIC_23 (MASK SMBALERT) (E7h)
      41. 7.7.41 MFR_SPECIFIC_25 (AVS_CONFIG) (E9h)
      42. 7.7.42 MFR_SPECIFIC_26 (AVS_ADDRESS) (EAh)
      43. 7.7.43 MFR_SPECIFIC_27 (AVS_DAC_DEFAULT) (EBh)
      44. 7.7.44 MFR_SPECIFIC_28 (AVS_CLAMP_HI) (ECh)
      45. 7.7.45 MFR_SPECIFIC_29 (AVS_CLAMP_LO) (EDh)
      46. 7.7.46 MFR_SPECIFIC_30 (TEMP_OFFSET) (EEh)
      47. 7.7.47 MFR_SPECIFIC_32 (API_OPTIONS) (F0h)
      48. 7.7.48 MFR_SPECIFIC_44 (DEVICE_CODE) (FCh)
  8. Applications and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Dual-Output Application
      2. 8.2.2 Design Requirements
      3. 8.2.3 Design Procedure
        1. 8.2.3.1  Switching Frequency Selection
        2. 8.2.3.2  Inductor Selection
        3. 8.2.3.3  Output Capacitor Selection
          1. 8.2.3.3.1 Output Voltage Deviation During Load Transient
          2. 8.2.3.3.2 Output Voltage Ripple
        4. 8.2.3.4  Input Capacitor Selection
        5. 8.2.3.5  VDD, BP5, BP3 Bypass Capacitor
        6. 8.2.3.6  R-C Snubber
        7. 8.2.3.7  Current and Temperature Sensor
        8. 8.2.3.8  Power Sequence Between the TPS40425 Device and Power Stage
        9. 8.2.3.9  Output Voltage Setting and Frequency Compensation Selection
        10. 8.2.3.10 Key PMBus Parameter Selection
          1. 8.2.3.10.1 MFR_SPECIFIC_21 (OPTIONS)
            1. 8.2.3.10.1.1 IOUT_CAL_GAIN
            2. 8.2.3.10.1.2 Enable and UVLO
            3. 8.2.3.10.1.3 Soft-Start Time
            4. 8.2.3.10.1.4 Overcurrent Threshold and Response
      4. 8.2.4 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
      1. 10.1.1 Layout Guidelines for TPS40425 Device
      2. 10.1.2 Layout Guidelines for Power Stage Device
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Device Support
      1. 11.1.1 Development Support
        1. 11.1.1.1 Texas Instruments Fusion Digital Power Designer
        2. 11.1.1.2 TPS40k Loop Compensation Tool
    2. 11.2 Trademarks
    3. 11.3 Electrostatic Discharge Caution
    4. 11.4 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Soft-Start Time

The TPS40425 device supports several soft-start times from 600 μs to 9 ms selected by the TON_RISE PMBus command. See the command description for full details on the levels and implementation. When selecting the soft-start time, ensure that the charging current for the output capacitors is carefully considered. In some applications (for example, those with large amounts of output capacitance) this current can lead to problems with nuisance tripping of the overcurrent protection circuitry. To ensure that these problems do not happen, the output capacitor charging current should be included when considering where to set the overcurrent threshold. The output capacitor charging current can be found using Equation 9:

Equation 9. TPS40425 EQ_9.gif

where

  • ICAP is the startup charging current of the output capacitance in A
  • VOUT is the output voltage of the converter in V
  • COUT is the total output capacitance in F
  • tSS is the selected soft-start time in seconds

With the charging current calculated, the overcurrent threshold can then be calibrated to the sum of the maximum load current and the output capacitor charging current plus some margin. The amount of margin required depends on the individual application, but 25% is a suggested starting point. More or less may be required.

NOTE

For 3-phase and 4-phase configurations, the soft-start time of both controllers must be programmed to the same value.