Description

The AFE4400 is a fully-integrated analog front-end (AFE) ideally suited for pulse oximeter applications. The device consists of a low-noise receiver channel with an integrated analog-to-digital converter (ADC), an LED transmit section, and diagnostics for sensor and LED fault detection. The device is a very configurable timing controller. This flexibility enables the user to have complete control of the device timing characteristics. To ease clocking requirements and provide a low-jitter clock to the AFE4400, an oscillator is also integrated that functions from an external crystal. The device communicates to an external microcontroller or host processor using an SPI™ interface.

The device is a complete AFE solution packaged in a single, compact VQFN-40 package (6 mm × 6 mm) and is specified over the operating temperature range of 0°C to 70°C.

Features

  • Fully-Integrated Analog Front-End for Pulse Oximeter Applications:
    • Flexible Pulse Sequencing and
      Timing Control
  • Transmit:
    • Integrated LED Driver
      (H-Bridge, Push, or Pull)
    • Dynamic Range: 95 dB
    • LED Current:
      • Programmable to 50 mA with 8-Bit Current Resolution
    • Low Power:
      • 100 µA + Average LED Current
    • Programmable LED On-Time
    • Independent LED2 and LED1 Current Reference
  • Receive Channel with High Dynamic Range:
    • 13 Noise-Free Bits
    • Low Power: < 670 µA at 3.3-V Supply
    • Integrated Digital Ambient Estimation and Subtraction
    • Flexible Receive Sample Time
    • Flexible Transimpedance Amplifier with Programmable LED Settings
  • Integrated Fault Diagnostics:
    • Photodiode and LED Open and
      Short Detection
    • Cable On and Off Detection
  • Supplies:
    • Rx = 2.0 V to 3.6 V
    • Tx = 3.0 V to 5.25 V
  • Package: Compact VQFN-40 (6 mm × 6 mm)
  • Specified Temperature Range: 0°C to 70°C

View more

Parametrics Compare all products in Medical Analog Front End

 
Resolution (Bits)
# Input Channels
Pin/Package
Sample Rate (max) (SPS)
Interface
Approx. Price (US$)
Reference Mode
Operating Temperature Range (C)
Architecture
AFE4400 AFE4490
22     22    
1     1    
40VQFN     40VQFN    
1.3KSPS     5KSPS    
Serial SPI     Serial SPI    
2.95 | 1ku     7.95 | 1ku    
Ext     Ext    
0 to 70     -40 to 85    
Delta-Sigma     Delta-Sigma    

Featured tools and software

Companion parts

Part # Name Product Family Comments
AFE4490   Integrated Analog Front End for Pulse Oximeters   ANALOG FRONT END - Medical Analog Front End    AFE4490 is similar to the AFE4400, but has higher performance.  
BQ2026   1.5K-Bit Serial EPROM with SDQ Interface   BATTERY MANAGEMENT PRODUCTS - Battery Protection, Authentication & Identification Solutions    BQ2026 is used for Authentication of medical cables and accessories  
AFE4300   Weigh Scale / Body Composition Analog Front End   ANALOG FRONT END - Medical Analog Front End    AFE4300 is AFE for body comp/weigh scales  
ADS1293   Complete Low Power Integrated Analog Front End for ECG Applications   ANALOG FRONT END - Medical Analog Front End    ADS1293 is AFE for wireless ECG  
Click Here