Packaging Information for Pitch: .8 mm

Pkg Pins Footprint Type Industry Standard Term Description Width
(mm)
Length
(mm)
Thickness
(mm)
Maximum Height
(mm)
JEDEC
CLZ 532 FC/CSP FC/CSP Plastic Grid Array 23 23 2.35 3.3 S-PBGA-N
DCE 36 SSOP SSOP Plastic Small Outline 7.5 15.39 2.54 2.64 R-PDSO-G
DCE 44 SSOP SSOP Plastic Small Outline 7.5 17.91 2.54 2.64 R-PDSO-G
DRJ 8   WSON WSON Plastic Small Outline 4 4 .67 .8 S-PDSO-N
DRM 8   VSON VSON Plastic Small Outline 4 4 .9 1 S-PDSO-N
FR 44 QFP QFP Plastic Flat Pack 10 10 1.75 2.25 S-PQFP-G
FT 64   DFP DFP Plastic Flat Pack 14 20 2 2.3 R-PTFP-G
FT 48   DFP DFP Plastic Flat Pack 14 20 2 2.3 R-PDFP-G
GDG 208   BGA BGA Plastic Grid Array 15 15 1.04 1.5 S-PBGA-N
GDK 532   FCBGA FCBGA Plastic Grid Array 23 23 1.8 2.8 S-PBGA-N
GDK 548 FCBGA FCBGA Plastic Grid Array 23 23 1.8 2.8 S-PBGA-N
GGB 128   BGA BGA Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
GGB 100   BGA BGA Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
GGB 144   BGA BGA Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
GGJ 144   PLGA PLGA Plastic Grid Array 12 12 .9 1.1 S-PLGA-N
GGM 80 BGA BGA Plastic Grid Array 10 10 .9 1.4 S-PBGA-N
GGM 100 BGA BGA Plastic Grid Array 10 10 .9 1.4 S-PBGA-N
GGT 100   BGA BGA Plastic Grid Array 11 11 .9 1.4 S-PBGA-N
GGU 144 BGA BGA Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
GGU 169 BGA BGA Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
GGV 63   BGA BGA Plastic Grid Array 8 8 .9 1.4 S-PBGA-N
GGV 64 BGA BGA Plastic Grid Array 8 8 .9 1.4 S-PBGA-N
GGW 208   BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 15 15 .9 1.4 S-PBGA-N
GGW 240 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 15 15 .9 1.4 S-PBGA-N
GGW 176 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 15 15 .9 1.4 S-PBGA-N
GGW 201   BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 15 15 .9 1.4 S-PBGA-N
GHB 64   BGA BGA Plastic Grid Array 9 13 .9 1.4 R-PBGA-N
GHB 79   BGA BGA Plastic Grid Array 9 13 .9 1.4 R-PBGA-N
GHH 179 BGA BGA Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
GHJ 201   BGA BGA Plastic Grid Array 13 13 .9 1.4 S-PBGA-N
GHK 306   BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
GHK 288 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
GHK 209 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
GHK 257 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
GHV 181   BGA BGA Plastic Grid Array 13 13 .9 1.4 S-PBGA-N
GJE 79   BGA BGA Plastic Grid Array 9 13 .9 1.1 R-PBGA-N
GJF 181   PLGA PLGA Plastic Grid Array 13 13 .9 1.1 S-PLGA-N
GJG 257 BGA BGA Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
GJG 209   BGA BGA Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
GKE 96 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 5.5 13.5 .9 1.4 R-PBGA-N
GKF 114 BGA BGA Plastic Grid Array 5.5 16 .9 1.4 R-PBGA-N
GKT 64   PLGA PLGA Plastic Grid Array 8 8 .9 1.1 S-PLGA-N
GKT 64   PLGA PLGA Plastic Grid Array 8 8 .9 1.1 S-PLGA-N
GLQ 208   PLGA PLGA Plastic Grid Array 15 15 .9 1.1 S-PLGA-N
GLS 384 FC/CSP FC/CSP Plastic Grid Array 18 18 2.35 2.8 S-PBGA-N
GLW 340 BGA BGA Plastic Grid Array 18 18 1.6 2.095 S-PBGA-N
GLZ 532 FCBGA FCBGA Plastic Grid Array 23 23 2.35 3.3 S-PBGA-N
GNM 144 CBGA CBGA Ceramic, Metal Grid Array 12 12 1.9 2.4 S-CBGA-N
GNY 384 FC/CSP FC/CSP Plastic Grid Array 18 18 1.9 2.35 S-PBGA-N
GRD 54 VFBGA VFBGA Plastic Grid Array 5.5 8 .8 1.2 R-PBGA-N
GTZ 697 FCBGA FCBGA Plastic Grid Array 24 24 2.48 3.1 S-PBGA-N
GTZ 737   FCBGA FCBGA Plastic Grid Array 24 24 2.48 3.1 S-PBGA-N
GUN 561   FCBGA FCBGA Plastic Grid Array 23 23 1.09 2.66 S-PBGA-N
GUT 529   FCBGA FCBGA Plastic Grid Array 19 19 2.48 3.1 S-PBGA-N
GVF 216 NFBGA NFBGA Plastic Grid Array 16 16 1.15 1.4 S-PBGA-N
GXG 64 BGA BGA Plastic Grid Array 8 8 1.01 1.45 S-PBGA-N
GZY 256   BGA BGA Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
GZZ 201 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 15 15 .9 1.4 S-PBGA-N
PAF 80   QFP QFP Plastic Flat Pack 14 20 3.1 3.1 R-PQFP-G
PBE 120   HQFP HQFP Plastic Flat Pack 28 28 3.4 4.1 S-PQFP-G
PBM 120 QFP QFP Plastic Flat Pack 28 28 3.4 4.1 S-PQFP-G
PBM 128   QFP QFP Plastic Flat Pack 28 28 3.4 4.1 S-PQFP-G
PBP 64   HTQFP HTQFP Plastic Flat Pack 14 14 1 1.2 S-PQFP-G
PBR 64   QFP QFP Plastic Flat Pack 14 14 1 1.2 S-PQFP-G
PF 64   QFP QFP Plastic Flat Pack 14 14 2.7 3.1 S-PQFP-G
PGM 44   HTQFP HTQFP Plastic Flat Pack 10 10 1 1.2 S-PQFP-G
PGS 44   HTQFP HTQFP Plastic Flat Pack 10 10 1 1.2 S-PQFP-G
PGT 44   TQFP TQFP Plastic Flat Pack 10 10 1 1.2 S-PQFP-G
PH 80 QFP QFP Plastic Flat Pack 14 20 2.7 3.1 R-PQFP-G
PHD 64   HTQFP HTQFP Plastic Flat Pack 14 14 1 1.2 S-PQFP-G
PJS 48 QFP QFP Plastic Flat Pack 12.1 12.1 2.6 2.7 S-PQFP-G
PJT 32 TQFP TQFP Plastic Flat Pack 7 7 1 1.2 S-PQFP-N
RHC 16   VQFN VQFN Plastic Flat Pack 4 4 .9 1 S-PQFP-N
RSF 12   WQFN WQFN Plastic Flat Pack 4 4 .75 .8 S-PQFP-N
VF 32 LQFP LQFP Plastic Flat Pack 7 7 1.4 1.6 S-PQFP-G
VFD 32   HLQFP HLQFP Plastic Flat Pack 7 7 1.4 1.6 S-PQFP-G
VFP 32   HLQFP HLQFP Plastic Flat Pack 7 7 1.4 1.6 S-PQFP-G
ZAY 167 BGA BGA Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
ZDK 548 FCBGA FCBGA Plastic Grid Array 23 23 1.8 2.8 S-PBGA-N
ZGU 144 BGA BGA Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
ZGV 64 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 8 8 .9 1.4 S-PBGA-N
ZGW 240 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 15 15 .9 1.4 S-PBGA-N
ZGW 208   BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 15 15 .9 1.4 S-PBGA-N
ZGW 201   BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 15 15 .9 1.4 S-PBGA-N
ZHH 179 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
ZHH 175   BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 12 12 .9 1.4 S-PBGA-N
ZHK 306   BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
ZHK 209 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
ZHK 257 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
ZHK 288 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 16 16 .9 1.4 S-PBGA-N
ZKE 96 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 5.5 13.5 .85 1.4 R-PBGA-N
ZKF 114 BGA MICROSTAR BGA MICROSTAR Plastic Grid Array 5.5 16 .95 1.4 R-PBGA-N
ZLZ 532 FCBGA FCBGA Plastic Grid Array 23 23 2.35 3.3 S-PBGA-N
ZRD 54 VFBGA VFBGA Plastic Grid Array 5.5 8 .8 1.2 R-PBGA-N
ZTZ 697 FCBGA FCBGA Plastic Grid Array 24 24 2.48 3.1 S-PBGA-N
ZTZ 737   FCBGA FCBGA Plastic Grid Array 24 24 2.48 3.1 S-PBGA-N
ZUN 561   FCBGA FCBGA Plastic Grid Array 23 23 1.09 2.66 S-PBGA-N
ZUT 529 FCBGA FCBGA Plastic Grid Array 19 19 2.48 3.1 S-PBGA-N
ZVA 64 BGA BGA Plastic Grid Array 8 8 .96 1.4 S-PBGA-N
ZVF 216 NFBGA NFBGA Plastic Grid Array 16 16 .96 1.4 S-PBGA-N