Description

The PMP2534 is composed of two times active clamp forward, delivering 0…35V@10Amax, two current limit functions to protect the 3.3V and 5V outputs and some interface for a microcntroller. The active clamps are constant voltage and/or constant current controllable by means of two PWM inputs. This power supply is suitable as general bench power generator from a desktop standard PSU as source.

View the Important Notice for TI Designs covering authorized use, intellectual property matters and disclaimers.


Parametrics
 PMP2534.1
(Output Voltage 1)
Vin (Min) (V)11.4
Vin (Max) (V)12.6
Vout (Nom) (V)35
Iout (Max) (A)10
Output Power (W)350
Isolated/Non-IsolatedIsolated
Input TypeDC
TopologyForward- Active Clamp

TI Devices (3)

Order samples, get tools and find more information on the TI products in this reference design.

Part Number Name Product Family Sample & Buy Design Kits & Evaluation Modules
TL1431  Precision Adjustable (Programmable) Shunt Reference  Voltage Reference  Sample & Buy Not Available
UCC2808-2  Low Power Current Mode Push-Pull PWM  Offline and Isolated DC/DC Controllers and Converters  Sample & Buy Not Available
UCC2897  Current Mode Active Clamp PWM Controller  Offline and Isolated DC/DC Controllers and Converters  Sample & Buy Not Available

Technical Documents

View the Important Notice for TI Designs covering authorized use, intellectual property matters and disclaimers.

User guides (1)
Title Abstract Type Size (KB) Date Views
PDF 401 14 Oct 2011 24
Design files (2)
Title Abstract Type Size (KB) Date Views
PDF 50 14 Oct 2011 31
PDF 378 14 Oct 2011 54


Support & Training

TI E2E Community

As a member of  myTI you can join the TI E2E™ Community  where you can ask questions, share ideas and collaborate with fellow engineers and TI experts

Content is provided "AS IS" by the respective TI and Community contributors and does not constitute TI specifications. See  Terms of use.

Engage in the Community

Blogs

Wikis

Visit the TI Wiki