SLVSIN3 May 2025 ADS9117 , ADS9118 , ADS9119
PRODUCTION DATA
Power down the ADS911x with a logic 0 on the PWDN pin or write 11b to the PD_CH field (address 0xC0, register bank 1). The device registers are initialized to the default values after power-up. Initialize the device with a sequence of register write operations; see the Initialization Sequence section.