SLUSEC9A October   2020  – March 2021 BQ25618E , BQ25619E

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Description (continued)
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Timing Requirements
    7. 8.7 Typical Characteristics
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Power-On-Reset (POR)
      2. 9.3.2 Device Power Up From Battery Without Input Source
      3. 9.3.3 Power Up From Input Source
        1. 9.3.3.1 Power Up REGN LDO
        2. 9.3.3.2 Poor Source Qualification
        3. 9.3.3.3 Input Source Type Detection (IINDPM Threshold)
          1. 9.3.3.3.1 PSEL Pins Sets Input Current Limit
        4. 9.3.3.4 Input Voltage Limit Threshold Setting (VINDPM Threshold)
        5. 9.3.3.5 Power Up Converter in Buck Mode
        6. 9.3.3.6 HIZ Mode with Adapter Present
      4. 9.3.4 Power Path Management
        1. 9.3.4.1 Narrow Voltage DC (NVDC) Architecture
        2. 9.3.4.2 Dynamic Power Management
        3. 9.3.4.3 Supplement Mode
      5. 9.3.5 Battery Charging Management
        1. 9.3.5.1 Autonomous Charging Cycle
        2. 9.3.5.2 Battery Charging Profile
        3. 9.3.5.3 Charging Termination
        4. 9.3.5.4 Thermistor Qualification
          1. 9.3.5.4.1 JEITA Guideline Compliance During Charging Mode
        5. 9.3.5.5 Charging Safety Timer
      6. 9.3.6 Ship Mode and QON Pin
        1. 9.3.6.1 BATFET Disable (Enter Ship Mode)
        2. 9.3.6.2 BATFET Enable (Exit Ship Mode)
        3. 9.3.6.3 BATFET Full System Reset
      7. 9.3.7 Status Outputs ( STAT, INT , PG )
        1. 9.3.7.1 Power Good Indicator (PG_STAT Bit; BQ25619E only)
        2. 9.3.7.2 Charging Status Indicator (STAT)
        3. 9.3.7.3 Interrupt to Host ( INT)
      8. 9.3.8 Protections
        1. 9.3.8.1 Voltage and Current Monitoring in Buck Mode
          1. 9.3.8.1.1 Input Overvoltage Protection (ACOV)
          2. 9.3.8.1.2 System Overvoltage Protection (SYSOVP)
        2. 9.3.8.2 Thermal Regulation and Thermal Shutdown
          1. 9.3.8.2.1 Thermal Protection in Buck Mode
        3. 9.3.8.3 Battery Protection
          1. 9.3.8.3.1 Battery Overvoltage Protection (BATOVP)
          2. 9.3.8.3.2 Battery Overdischarge Protection
          3. 9.3.8.3.3 System Overcurrent Protection
      9. 9.3.9 Serial Interface
        1. 9.3.9.1 Data Validity
        2. 9.3.9.2 START and STOP Conditions
        3. 9.3.9.3 Byte Format
        4. 9.3.9.4 Acknowledge (ACK) and Not Acknowledge (NACK)
        5. 9.3.9.5 Slave Address and Data Direction Bit
        6. 9.3.9.6 Single Read and Write
        7. 9.3.9.7 Multi-Read and Multi-Write
    4. 9.4 Device Functional Modes
      1. 9.4.1 Host Mode and Default Mode
    5. 9.5 Register Maps
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 Inductor Selection
        2. 10.2.2.2 Input Capacitor and Resistor
        3. 10.2.2.3 Output Capacitor
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Device Support
      1. 13.1.1 Third-Party Products Disclaimer
    2. 13.2 Documentation Support
      1. 13.2.1 Related Documentation
    3. 13.3 Receiving Notification of Documentation Updates
    4. 13.4 Support Resources
    5. 13.5 Trademarks
    6. 13.6 Electrostatic Discharge Caution
    7. 13.7 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Charging Safety Timer

The device has a built-in safety timer to prevent extended charging cycle due to abnormal battery conditions. The safety timer is 2 hours when the battery is below VBATLOWV threshold and 10 hours (10/20 hours in REG05[2] ) when the battery is higher than VBATLOWV threshold. When the safety timer expires, STAT pin is blinking at 1 Hz to report a safety timer expiration fault.

The user can program the fast charge safety timer through I2C (CHG_TIMER bit REG05[2]). When safety timer expires, the fault register CHRG_FAULT bits (REG09[5:4]) are set to 11 and an INT is asserted to the host. The safety timer (both fast charge and pre-charge) can be disabled through I2C by setting EN_TIMER bit.

During IINDPM/VINDPM regulation, thermal regulation, or JEITA cool/warm when fast charge current is reduced,the safety timer counts at a half clock rate, because the actual charge current is likely below the setting. For example, if the charger is in input current regulation (IINDPM_STAT = 1) throughout the whole charging cycle, and the safety time is set to 10 hours, the safety timer will expire in 20 hours. This half clock rate feature can be disabled by writing 0 to the TMR2X_EN bit.

During faults of BAT_FAULT, NTC_FAULT that lead to charging suspend, safety timer is suspended as well. Once the fault goes away, timer resumes. If user stops the current charging cycle, and start again, timer gets reset (toggle CE pin or CHG_CONFIG bit).