7 |
EN_AUTO_IBATDIS |
R/W |
1h |
Reset by:
REG_RST
|
Enable the auto battery discharging during the battery OVP fault
Type : RW
POR: 1b
0h = The charger will NOT apply a discharging current on BAT during battery OVP
1h = The charger will apply a discharging current on BAT during battery OVP
|
6 |
FORCE_IBATDIS |
R/W |
0h |
Reset by:
REG_RST
|
Force a battery discharging current
Type : RW
POR: 0b
0h = IDLE (default)
1h = Force the charger to apply a discharging current on BAT regardless the battery OVP status
|
5 |
EN_CHG |
R/W |
1h |
Reset by:
WATCHDOG
REG_RST
|
Charger Enable Configuration
Type : RW
POR: 1b
0h = Charge Disable
1h = Charge Enable (default)
|
4 |
EN_ICO |
R/W |
0h |
Reset by:
REG_RST
|
Input Current Optimizer (ICO) Enable
Type : RW
POR: 0b
0h = Disable ICO (default)
1h = Enable ICO
|
3 |
FORCE_ICO |
R/W |
0h |
Reset by:
WATCHDOG
REG_RST
|
Force start input current optimizer (ICO)
Note: This bit can only be set and returns 0 after ICO starts. This bit only valid when EN_ICO = 1
Type : RW
POR: 0b
0h = Do NOT force ICO (Default)
1h = Force ICO start
|
2 |
EN_HIZ |
R/W |
0h |
Reset by:
REG_RST
|
Enable HIZ mode.
This bit will be also reset to 0, when the adapter is plugged in at VBUS.
Type : RW
POR: 0b
0h = Disable (default)
1h = Enable
|
1 |
EN_TERM |
R/W |
1h |
Reset by:
WATCHDOG
REG_RST
|
Enable termination
Type : RW
POR: 1b
0h = Disable
1h = Enable (default)
|
0 |
RESERVED |
R |
0h |
|
Reserved |