7 |
IBAT_REG_MASK |
R/W |
0h |
Reset by:
REG_RST
|
IBAT regulation mask flag
Type : RW
POR: 0b
0h = enter or exit IBAT regulation does produce INT
1h = enter or exit IBAT regulation does NOT produce INT
|
6 |
VBUS_OVP_MASK |
R/W |
0h |
Reset by:
REG_RST
|
VBUS over-voltage mask flag
Type : RW
POR: 0b
0h = entering VBUS OVP does produce INT
1h = entering VBUS OVP does NOT produce INT
|
5 |
VBAT_OVP_MASK |
R/W |
0h |
Reset by:
REG_RST
|
VBAT over-voltage mask flag
Type : RW
POR: 0b
0h = entering VBAT OVP does produce INT
1h = entering VBAT OVP does NOT produce INT
|
4 |
IBUS_OCP_MASK |
R/W |
0h |
Reset by:
REG_RST
|
IBUS over-current mask flag
Type : RW
POR: 0b
0h = IBUS OCP fault does produce INT
1h = IBUS OCP fault does NOT produce INT
|
3 |
IBAT_OCP_MASK |
R/W |
0h |
Reset by:
REG_RST
|
IBAT over-current mask flag
Type : RW
POR: 0b
0h = IBAT OCP fault does produce INT
1h = IBAT OCP fault does NOT produce INT
|
2 |
CONV_OCP_MASK |
R/W |
0h |
Reset by:
REG_RST
|
Converter over-current mask flag
Type : RW
POR: 0b
0h = Converter OCP fault does produce INT
1h = Converter OCP fault does NOT produce INT
|
1 |
VAC2_OVP_MASK |
R/W |
0h |
Reset by:
REG_RST
|
VAC2 over-voltage mask flag
Type : RW
POR: 0b
0h = entering VAC2 OVP does produce INT
1h = entering VAC2 OVP does NOT produce INT
|
0 |
VAC1_OVP_MASK |
R/W |
0h |
Reset by:
REG_RST
|
VAC1 over-voltage mask flag
Type : RW
POR: 0b
0h = entering VAC1 OVP does produce INT
1h = entering VAC1 OVP does NOT produce INT
|