SLOS893D September 2014 – August 2025 DRV2624
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
When automatic braking into standby is disabled (AUTO_BRK_INTO_STBY bit set to 0), playback can be triggered in both RTP and waveform sequencer modes with internal trigger by writing a 1 to the GO bit, and stopped by writing a 0 to the GO bit. Playback can also be triggered by the external trigger by following the trigger-pulse or trigger-level specifications (see Figure 7-4 and Figure 7-5 for details). Note that internal trigger is not available if the external trigger pin is set to trigger-level (TRIG_PIN_FUNC = 1)
RTP playback (MODE[1:0] = 0), once triggered, runs indefinitely until the waveform is stopped. The waveform sequencer (MODE[1:0] = 1) runs until the sequencer reaches the end point and automatically goes into standby without a cancel trigger being received, unless an infinite loop is requested.