SLOS893D September 2014 – August 2025 DRV2624
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
The rated voltage is the driving voltage that the driver outputs during steady state. However, in closed-loop drive mode, temporarily having an output voltage that is higher than the rated voltage is possible.
The RATED_VOLTAGE[7:0] parameter sets the rated voltage for the closed-loop drive modes.
In open-loop mode, the RATED_VOLTAGE[7:0] parameter is ignored. Instead, the OD_CLAMP[7:0] parameter is used to set the full-scale voltage for the open-loop drive modes.
The auto-calibration routine uses the RATED_VOLTAGE[7:0] and OD_CLAMP[7:0] bits as inputs and therefore these registers must be written before calibration is performed. Any modification of this register value is followed by calibration to appropriately set A_CAL_BEMF[7:0].