SNAS778D June 2021 – July 2024 HDC3020 , HDC3021 , HDC3022
PRODUCTION DATA
The Status Register contains real-time information about the operating state of the HDC302x, as documented in Table 7-14. There are two commands associated with the Status Register: Read Content and Clear Content, as documented in Table 7-4 and illustrated in Figure 7-24 and Figure 7-25.
| BIT | DEFAULT | DESCRIPTION |
|---|---|---|
| 15 | 1 | Overall Alert Status 0 = No active alerts 1 = At least one tracking or reset alert |
| 14 | 0 | Reserved |
| 13 | 0 | Heater Status 0 = Heater Disabled 1 = Heater Enabled |
| 12 | 0 | Reserved |
| 11 | 0 | RH Tracking Alert . Mirrored on the Alert pin 0 = No RH alert 1 = RH alert |
| 10 | 0 | T Tracking Alert . Mirrored on the Alert Pin 0 = No T alert 1 = T alert |
| 9 | 0 | RH High Tracking Alert 0 = No RH High alert 1 = RH High alert |
| 8 | 0 | RH Low Tracking Alert 0 = No RH Low alert 1 = RH Low alert |
| 7 | 0 | T High Tracking Alert 0 = No T High alert 1 = T High alert |
| 6 | 0 | T Low Tracking Alert 0 = No T Low alert 1 = T Low alert |
| 5 | 0 | Reserved |
| 4 | 1 | Device Reset Detected Alert. Mirrored on Alert pin. 0 = No reset detected since last clearing of Status Register 1 = Device reset detected (via hard reset, soft reset command or supply on) |
| 3 | 0 | Reserved |
| 2 | 0 | Reserved |
| 1 | 0 | Reserved |
| 0 | 0 | Checksum verification of last data write 0 = Pass (correct checksum received) 1 = Fail (incorrect checksum received). Can be cleared only by successful data write or by reset event. |
Figure 7-24 I2C Command Sequence: Read Status Register
Figure 7-25 I2C Command Sequence: Clear Status RegisterThe Clear Status Register command clears only the reset and tracking bits in the status register.