SLLSFK0C August   2021  – November 2021 ISO6760 , ISO6761 , ISO6762 , ISO6763

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9.     Electrical Characteristics—5-V Supply
    10. 6.9  Supply Current Characteristics—5-V Supply
    11. 6.10 Electrical Characteristics—3.3-V Supply
    12. 6.11 Supply Current Characteristics—3.3-V Supply
    13. 6.12 Electrical Characteristics—2.5-V Supply 
    14. 6.13 Supply Current Characteristics—2.5-V Supply
    15.     Electrical Characteristics—1.8-V Supply
    16. 6.14 Supply Current Characteristics—1.8-V Supply
    17. 6.15 Switching Characteristics—5-V Supply
    18. 6.16 Switching Characteristics—3.3-V Supply
    19. 6.17 Switching Characteristics—2.5-V Supply
    20. 6.18 Switching Characteristics—1.8-V Supply
    21. 6.19 Insulation Characteristics Curves
    22. 6.20 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Electromagnetic Compatibility (EMC) Considerations
    4. 8.4 Device Functional Modes
      1. 8.4.1 Device I/O Schematics
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
        1. 9.2.3.1 Insulation Lifetime
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 PCB Material
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information
    1. 13.1 Package Option Addendum
    2. 13.2 Tape and Reel Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Safety-Related Certifications

VDE CSA UL CQC TUV
Plan to certify according to DIN VDE V 0884-11:2017- 01 Plan to certify according to IEC 62368-1, IEC 61010-1 and IEC 60601-1 Plan to certify according to UL 1577 Component Recognition Program Plan to certify according to GB4943.1-2011 Plan to certify according to EN 61010-1:2010/ A1:2019 and EN 62368-1:2014
Maximum transient isolation
voltage, 7071 VPK;
Maximum repetitive peak isolation
voltage, 2121 VPK;
Maximum surge isolation
voltage, 6250 VPK
600 VRMS reinforced insulation per CSA 62368-1:19 and IEC 62368-1:2018; 600 VRMS reinforced insulation per CSA 61010-1-12+A1 and IEC 61010-1 3rd Ed (pollution degree 2, material group I); 


2 MOPP (Means of Patient Protection) per CSA 60601-1-14 and IEC 60601-1 Ed.3+A1, 250 VRMS max working voltage
 
Single protection,
5000 VRMS
Reinforced insulation, Altitude ≤ 5000 m, Tropical Climate,
700 VRMS
maximum working voltage
5000 VRMS reinforced insulation per EN 61010-1:2010/A1:2019 and EN 62368-1:2014 up to working voltage of 600 VRMS
Certificate planned Certificate planned Certificate planned Certificate planned Certificate planned