Bypass the input pin to ground with a bypass
capacitor.
The optimum placement is closest to the
VIN of the device and the GND of the system. Care must be taken
to minimize the loop area formed by the bypass capacitor connection, the INPUT
pin, and the GND pin of the system.
For operation at a full-rated load, use wide
trace lengths to eliminate IR drop and heat dissipation.