As with any power conversion device, the LM656x0-Q1 dissipates internal power while operating.
The effect of this power dissipation is to raise the internal temperature of the
converter above ambient temperature. The internal die temperature (TJ) is
a function of the following:
- Ambient temperature
- Power loss
- Effective thermal resistance,
RθJA of the device
- PCB layout
The maximum internal die temperature for the
LM656x0-Q1 must be limited to 150°C. This limit establishes a limit on the
maximum device power dissipation and, therefore, the load current.
Equation 24 shows the relationships between the important parameters. Larger ambient
temperatures (T
A) and larger values of R
θJA reduce the maximum
available output current. The converter efficiency can be estimated by using the
curves provided in the
Application Curves section. If the desired operating conditions cannot be found in one of
the curves, then interpolation can be used to estimate the efficiency.
Alternatively, the EVM can be adjusted to match the desired application requirements
and the efficiency can be measured directly. The correct value of R
θJA is
more difficult to estimate. As stated in the
Semiconductor and IC Package Thermal
Metrics application note, the JESD 51-7 value of R
θJA
given in the
Thermal Information section is not valid for design purposes and must not be used to estimate
the thermal performance of the device in a real application. The JESD 51-7 values
reported in the
Thermal Information table were measured under a specific set of conditions that are rarely
obtained in an actual application.
Equation 24.
where
- η = efficiency
- TA = ambient temperature
- TJ = junction temperature
- RθJA = the effective thermal resistance of the IC junction to the air, mainly through
the PCB
The effective RθJA is a critical
parameter and depends on many factors. The following are the most critical
parameters:
- Power dissipation
- Air temperature
- Airflow
- PCB area
- Copper heat-sink area
- Number of thermal vias under
or near the package
- Adjacent component
placement
Typical curves of maximum output
current versus ambient temperature are shown in Derating Curves for a good thermal layout.
Use Thermal Design Resources as a guide for thermal PCB design and estimating RθJA for a
given application environment.