SBOSAA7 September 2025 OPA598
PRODUCTION DATA
The OPA598 features an internal thermal shutdown feature. The op amp output stage disables when the junction temperature reaches 170°C. After the junction temperature cools to 150°C, the output stage is enabled, and the op amp resumes normal operation. In the event of an overtemperature condition a thermal flag trips. This flag is an open-drain output designed to connect to standard low-voltage logic circuitry, such as an MCU.