SLOS081M February   1977  – December 2021 TL081 , TL081A , TL081B , TL081H , TL082 , TL082A , TL082B , TL082H , TL084 , TL084A , TL084B , TL084H

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings: TL08xH
    2. 6.2  Absolute Maximum Ratings: All Other Devices
    3. 6.3  ESD Ratings: TL08xH
    4. 6.4  ESD Ratings: All Other Devices
    5. 6.5  Recommended Operating Conditions: TL08xH
    6. 6.6  Recommended Operating Conditions: All Other Devices
    7. 6.7  Thermal Information for Single Channel: TL081H
    8. 6.8  Thermal Information for Dual Channel: TL082H
    9. 6.9  Thermal Information for Quad Channel: TL084H
    10. 6.10 Thermal Information: All Other Devices
    11. 6.11 Electrical Characteristics: TL08xH
    12. 6.12 Electrical Characteristics for TL08xC, TL08xxC, and TL08xI
    13. 6.13 Electrical Characteristics for TL08xM and TL084x
    14. 6.14 Switching Characteristics
    15. 6.15 Dissipation Rating Table
    16. 6.16 Typical Characteristics: TL08xH
    17. 6.17 Typical Characteristics: All Other Devices
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Total Harmonic Distortion
      2. 8.3.2 Slew Rate
    4. 8.4 Device Functional Modes
  9. Applications and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Applications
      1. 9.2.1 Inverting Amplifier Application
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Curve
    3. 9.3 System Examples
      1. 9.3.1 General Applications
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Examples
  12. 12Device and Documentation Support
    1. 12.1 Receiving Notification of Documentation Updates
    2. 12.2 Support Resources
    3. 12.3 Trademarks
    4. 12.4 Electrostatic Discharge Caution
    5. 12.5 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • D|8
  • P|8
  • PS|8
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics for TL08xM and TL084x

VCC± = ±15 V (unless otherwise noted)
PARAMETERTEST CONDITIONS(1)TATL081M, TL082MTL084Q, TL084MUNIT
MINTYPMAXMINTYPMAX
VIOInput offset voltageVO = 0, RS = 50 Ω25°C3639mV
Full range915
αVIOTemperature
coefficient of input
offset voltage
VO = 0, RS = 50 ΩFull range1818μV/°C
IIOInput offset current(2)VO = 025°C51005100pA
125°C2020nA
IIBInput bias current(2)VO = 025°C3020030200pA
125°C5050nA
VICRCommon-mode
input voltage range
25°C±11–12
to
15
±11–12
to
15
V
VOMMaximum peak
output voltage swing
RL = 10 kΩ25°C±12±13.5±12±13.5V
RL ≥ 10 kΩFull range±12±12
RL ≥ 2 kΩ±10±12±10±12
AVDLarge-signal differential voltage amplificationVO = ±10 V, RL ≥ 2 kΩ25°C2520025200V/mV
Full range1515
B1Unity-gain bandwidth25°C33MHz
riInput resistance25°C10121012
CMRRCommon-mode
rejection ratio
VIC = VICRmin,
VO = 0, RS = 50 Ω
25°C80868086dB
kSVRSupply-voltage
rejection ratio
(ΔVCC±/ΔVIO)
VCC = ±15 V to ±9 V,
VO = 0, RS = 50 Ω
25°C80868086dB
ICCSupply current
(each amplifier)
VO = 0, No load25°C1.42.81.42.8mA
VO1/VO2Crosstalk attenuationAVD = 10025°C120120dB
All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified.
Input bias currents of a FET-input operational amplifier are normal junction reverse currents, which are temperature sensitive, as shown in Figure 6-52. Pulse techniques must be used that maintain the junction temperatures as close to the ambient temperature as possible.