SNIS214E june   2021  – july 2023 TMP114

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Device Comparison
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 I2C Interface Timing
    7. 7.7 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 1.2 V Compatible Logic Inputs
      2. 8.3.2 Cyclic Redundancy Check (CRC)
      3. 8.3.3 Temperature Limits
      4. 8.3.4 Slew Rate Warning
      5. 8.3.5 NIST Traceability
    4. 8.4 Device Functional Modes
      1. 8.4.1 Continuous Conversion Mode
      2. 8.4.2 Shutdown Mode
        1. 8.4.2.1 One-Shot Temperature Conversions
    5. 8.5 Programming
      1. 8.5.1 Temperature Data Format
      2. 8.5.2 I2C and SMBus Interface
      3. 8.5.3 Device Address
      4. 8.5.4 Bus Transactions
        1. 8.5.4.1 Auto-Increment
        2. 8.5.4.2 Writes
          1. 8.5.4.2.1 CRC Enabled Writes
        3. 8.5.4.3 Reads
          1. 8.5.4.3.1 CRC Enabled Reads
        4. 8.5.4.4 General Call Reset Function
        5. 8.5.4.5 Time-Out Function
        6. 8.5.4.6 Coexist on I3C MixedBus
        7. 8.5.4.7 Cyclic Redundancy Check Implementation
    6. 8.6 Register Map
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Separate I2C Pullup and Supply Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
    3. 9.3 Equal I2C Pullup and Supply Voltage Application
      1. 9.3.1 Design Requirements
      2. 9.3.2 Detailed Design Procedure
    4. 9.4 Power Supply Recommendations
    5. 9.5 Layout
      1. 9.5.1 Layout Guidelines
      2. 9.5.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Receiving Notification of Documentation Updates
    2. 10.2 Support Resources
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 Glossary
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • YMT|4
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Detailed Design Procedure

The TMP114 will convert temperature at a default 250 ms interval with an adjustable conversion period between 6.4 ms and 2 s. The SDA and SCL pin voltage of the TMP114 can be at a higher voltage than the VDD pin voltage, removing the need for power sequencing when using the TMP114.

The TMP114 comes in an ultra-small body and z-height package the user can place as close to temperature sources as possible for better thermal coupling.