SLVSGK4A November   2021  – June 2022 TPS22953-Q1 , TPS22954-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Device Comparison Table
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3.     Recommended Operating Conditions
    4. 7.3  Thermal Information
    5. 7.4  Electrical Characteristics
    6. 7.5  Electrical Characteristics – VBIAS = 5 V
    7. 7.6  Electrical Characteristics – VBIAS = 3.3 V
    8. 7.7  Electrical Characteristics – VBIAS = 2.5 V
    9. 7.8  Switching Characteristics – CT = 1000 pF
    10. 7.9  Switching Characteristics – CT = 0 pF
    11. 7.10 Typical DC Characteristics
    12. 7.11 Typical Switching Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  On and Off Control (EN Pin)
      2. 9.3.2  Voltage Monitoring (SNS Pin)
      3. 9.3.3  Power Good (PG Pin)
      4. 9.3.4  Supervisor Fault Detection and Automatic Restart
      5. 9.3.5  Manual Restart
      6. 9.3.6  Thermal Shutdown
      7. 9.3.7  Reverse Current Blocking (TPS22953-Q1 Only)
      8. 9.3.8  Quick Output Discharge (QOD) (TPS22954-Q1 Only)
      9. 9.3.9  VIN and VBIAS Voltage Range
      10. 9.3.10 Adjustable Rise Time (CT Pin)
      11. 9.3.11 Power Sequencing
    4. 9.4 Device Functional Modes
  10. 10Application and Implementation
    1. 10.1 Application Information
      1. 10.1.1 Input to Output Voltage Drop
      2. 10.1.2 Thermal Considerations
      3. 10.1.3 Automatic Power Sequencing
      4. 10.1.4 Monitoring a Downstream Voltage
      5. 10.1.5 Monitoring the Input Voltage
      6. 10.1.6 Break-Before-Make Power MUX (TPS22953-Q1 Only)
      7. 10.1.7 Make-Before-Break Power MUX (TPS22953-Q1 Only)
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 Inrush Current
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Documentation Support
      1. 13.1.1 Related Documentation
    2. 13.2 Receiving Notification of Documentation Updates
    3. 13.3 Support Resources
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Input to Output Voltage Drop

The input to output voltage drop in the device is determined by the RON of the device and the load current. The RON of the device depends upon the VIN and VBIAS conditions of the device. Refer to the RON specification of the device in the Electrical Characteristics table of this data sheet. After the RON of the device is determined based upon the VIN and VBIAS voltage conditions, use Equation 5 to calculate the input to output voltage drop.

Equation 5. GUID-121F0E1B-EA52-4E67-BD5D-71FC8B43E7B7-low.gif

where

  • ΔV is the voltage drop from IN to OUT
  • ILOAD is the load current
  • RON is the On-Resistance of the device for a specific VIN and VBIAS

An appropriate ILOAD must be chosen such that the IMAX specification of the device is not violated.