SLUSBO6C JANUARY   2014  – October 2018 TPS40425

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
    1.     Device Images
      1. 3.1 Simplified Application Diagram (Dual Output)
  4. Revision History
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 Handling Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Asynchronous Pulse Injection (API)
      2. 7.3.2  Adaptive Voltage Scaling (AVS)
      3. 7.3.3  Switching Frequency and Synchronization
      4. 7.3.4  Voltage Reference
      5. 7.3.5  Output Voltage and Remote Sensing Amplifier
      6. 7.3.6  Current Sensing and Temperature Sensing Modes
        1. 7.3.6.1 Non Smart-Power Operation
        2. 7.3.6.2 Smart-Power Operation.
      7. 7.3.7  Current Sensing
      8. 7.3.8  Temperature Sensing
      9. 7.3.9  Current Sharing
      10. 7.3.10 Linear Regulators
      11. 7.3.11 Power Sequence Between TPS40425 Device and Power Stage
      12. 7.3.12 PWM Signal
        1. 7.3.12.1 PWM Behavior During Soft-start Operation
      13. 7.3.13 Startup and Shutdown
      14. 7.3.14 Pre-Biased Output Start-up
      15. 7.3.15 PGOOD Indication
      16. 7.3.16 Overcurrent Protection
      17. 7.3.17 Overvoltage/Undervoltage Protection
      18. 7.3.18 Overtemperature Fault Protection
      19. 7.3.19 Input Undervoltage Lockout (UVLO)
      20. 7.3.20 Fault Communication
      21. 7.3.21 Fault Protection Summary
    4. 7.4 Device Functional Modes
    5. 7.5 Programming
      1. 7.5.1 Multi-Phase Applications
    6. 7.6 Register Maps
      1. 7.6.1 PMBus General Description
      2. 7.6.2 PMBus Functionality
        1. 7.6.2.1 PMBus Address
        2. 7.6.2.2 PMBus Connections
        3. 7.6.2.3 PMBus Data Format
        4. 7.6.2.4 PMBus Output Voltage Adjustment
          1. 7.6.2.4.1 No Margin Voltage
          2. 7.6.2.4.2 Margin High Voltage State
          3. 7.6.2.4.3 Margin Low State
      3. 7.6.3 Reading the Output Current
      4. 7.6.4 Soft-Start Time
      5. 7.6.5 Turn-On/Turn-Off Delay and Sequencing
    7. 7.7 Supported PMBus Commands
      1. 7.7.1  PAGE (00h)
      2. 7.7.2  OPERATION (01h)
      3. 7.7.3  ON_OFF_CONFIG (02h)
      4. 7.7.4  CLEAR_FAULTS (03h)
      5. 7.7.5  WRITE_PROTECT (10h)
      6. 7.7.6  STORE_USER_ALL (15h)
      7. 7.7.7  RESTORE_USER_ALL (16h)
      8. 7.7.8  CAPABILITY (19h)
      9. 7.7.9  VOUT_MODE (20h)
      10. 7.7.10 VIN_ON (35h)
      11. 7.7.11 VIN_OFF (36h)
      12. 7.7.12 IOUT_CAL_GAIN (38h)
      13. 7.7.13 IOUT_CAL_OFFSET (39h)
      14. 7.7.14 IOUT_OC_FAULT_LIMIT (46h)
      15. 7.7.15 IOUT_OC_FAULT_RESPONSE (47h)
      16. 7.7.16 IOUT_OC_WARN_LIMIT (4Ah)
      17. 7.7.17 OT_FAULT_LIMIT (4Fh)
      18. 7.7.18 OT_WARN_LIMIT (51h)
      19. 7.7.19 TON_RISE (61h)
      20. 7.7.20 STATUS_BYTE (78h)
      21. 7.7.21 STATUS_WORD (79h)
      22. 7.7.22 STATUS_VOUT (7Ah)
      23. 7.7.23 STATUS_IOUT (7Bh)
      24. 7.7.24 STATUS_TEMPERATURE (7Dh)
      25. 7.7.25 STATUS_CML (7Eh)
      26. 7.7.26 STATUS_MFR_SPECIFIC (80h)
      27. 7.7.27 READ_VOUT (8Bh)
      28. 7.7.28 READ_IOUT (8Ch)
      29. 7.7.29 READ_TEMPERATURE_2 (8Eh)
      30. 7.7.30 PMBus_REVISION (98h)
      31. 7.7.31 MFR_SPECIFIC_00 (D0h)
      32. 7.7.32 MFR_SPECIFIC_04 (VREF_TRIM) (D4h)
      33. 7.7.33 MFR_SPECIFIC_05 (STEP_VREF_MARGIN_HIGH) (D5h)
      34. 7.7.34 MFR_SPECIFIC_06 (STEP_VREF_MARGIN_LOW) (D6h)
      35. 7.7.35 MFR_SPECIFIC_07 (PCT_VOUT_FAULT_PG_LIMIT) (D7h)
      36. 7.7.36 MFR_SPECIFIC_08 (SEQUENCE_TON_TOFF_DELAY) (D8h)
      37. 7.7.37 MFR_SPECIFIC_16 (COMM_EEPROM_SPARE) (E0h)
      38. 7.7.38 MFR_SPECIFIC_21 (OPTIONS) (E5h)
      39. 7.7.39 MFR_SPECIFIC_22 (PWM_OSC_SELECT) (E6h)
      40. 7.7.40 MFR_SPECIFIC_23 (MASK SMBALERT) (E7h)
      41. 7.7.41 MFR_SPECIFIC_25 (AVS_CONFIG) (E9h)
      42. 7.7.42 MFR_SPECIFIC_26 (AVS_ADDRESS) (EAh)
      43. 7.7.43 MFR_SPECIFIC_27 (AVS_DAC_DEFAULT) (EBh)
      44. 7.7.44 MFR_SPECIFIC_28 (AVS_CLAMP_HI) (ECh)
      45. 7.7.45 MFR_SPECIFIC_29 (AVS_CLAMP_LO) (EDh)
      46. 7.7.46 MFR_SPECIFIC_30 (TEMP_OFFSET) (EEh)
      47. 7.7.47 MFR_SPECIFIC_32 (API_OPTIONS) (F0h)
      48. 7.7.48 MFR_SPECIFIC_44 (DEVICE_CODE) (FCh)
  8. Applications and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Dual-Output Application
      2. 8.2.2 Design Requirements
      3. 8.2.3 Design Procedure
        1. 8.2.3.1  Switching Frequency Selection
        2. 8.2.3.2  Inductor Selection
        3. 8.2.3.3  Output Capacitor Selection
          1. 8.2.3.3.1 Output Voltage Deviation During Load Transient
          2. 8.2.3.3.2 Output Voltage Ripple
        4. 8.2.3.4  Input Capacitor Selection
        5. 8.2.3.5  VDD, BP5, BP3 Bypass Capacitor
        6. 8.2.3.6  R-C Snubber
        7. 8.2.3.7  Current and Temperature Sensor
        8. 8.2.3.8  Power Sequence Between the TPS40425 Device and Power Stage
        9. 8.2.3.9  Output Voltage Setting and Frequency Compensation Selection
        10. 8.2.3.10 Key PMBus Parameter Selection
          1. 8.2.3.10.1 MFR_SPECIFIC_21 (OPTIONS)
            1. 8.2.3.10.1.1 IOUT_CAL_GAIN
            2. 8.2.3.10.1.2 Enable and UVLO
            3. 8.2.3.10.1.3 Soft-Start Time
            4. 8.2.3.10.1.4 Overcurrent Threshold and Response
      4. 8.2.4 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
      1. 10.1.1 Layout Guidelines for TPS40425 Device
      2. 10.1.2 Layout Guidelines for Power Stage Device
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Device Support
      1. 11.1.1 Development Support
        1. 11.1.1.1 Texas Instruments Fusion Digital Power Designer
        2. 11.1.1.2 TPS40k Loop Compensation Tool
    2. 11.2 Trademarks
    3. 11.3 Electrostatic Discharge Caution
    4. 11.4 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

STATUS_VOUT (7Ah)

Format Unsigned binary
Description The STATUS_VOUT command returns one byte of information relating to the status of the converter's output voltage related faults. The PMBus core is notified of these fault conditions via the 2 input pins labeled OVF and UVF. The PMBus core then communicates these faults to the host through its serial communication channel.
STATUS_VOUT is a paged register. In order to access this register for channel 1 of the TPS40425 device, PAGE must be set to 0. In order to access this register for channel 2 of TPS40425 controller, PAGE must be set to 1. For simultaneous access of channels 1 and 2, PAGE command must be set to 11.
Default 00000000 (binary)
PAGE0, PAGE1
read only
7 6 5 4 3 2 1 0
OVF 0 0 UVF 0 0 0 0
Bits Field Name Description
7 OVF (= VOUT OV Fault in the PMBus Specification)

(Format: binary)

Output Over-Voltage Fault

Set based upon the value stored in MFR_SPECIFIC_07 (D7h). If the channel is configured as a slave this bit are set to 0 (this bit is only reflected in the master).

0: (Default) An output over-voltage fault has not occurred.

1: An output over-voltage fault has occurred.
6:5 0 Default: 0
4 UVF (= VOUT UV Fault in the PMBus Specification)

(Format: binary)

Output Under-Voltage Fault

Set based upon the value stored in MFR_SPECIFIC_07 (D7h). If the channel is configured as a slave this bit are set to 0 (this bit is only reflected in the master). The UV fault indicates only an under-voltage condition at the FB pin and may not necessarily reflect an over-current situation. However, during an output crowbar short condition, the FB may sag below the UV threshold level before the current reaches the OC threshold, resulting in a UV fault. If the IOUT_OC_FAULT_ RESPONSE register is selected to the retry setting, and the output short is persistent, an over-current fault are triggered for subsequent startup retry attempts.
0: (Default) An output under-voltage fault has not occurred.

1: An output under-voltage fault has occurred.
3:0 0 Default: 0