JAJSHJ9A June   2019  – January 2021 BQ25125

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 説明
  4. Revision History
  5. 概要 (続き)
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Timing Requirements
    7. 8.7 Typical Characteristics
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  Ship Mode
        1. 9.3.1.1 Ship Mode Entry and Exit
      2. 9.3.2  High Impedance Mode
      3. 9.3.3  Active Battery Only Connected
      4. 9.3.4  Voltage Based Battery Monitor
      5. 9.3.5  Sleep Mode
      6. 9.3.6  Input Voltage Based Dynamic Power Management (VIN(DPM))
      7. 9.3.7  Input Overvoltage Protection and Undervoltage Status Indication
      8. 9.3.8  Battery Charging Process and Charge Profile
      9. 9.3.9  Battery Supplement Mode
      10. 9.3.10 Default Mode
      11. 9.3.11 Termination and Pre-Charge Current Programming by External Components (IPRETERM)
      12. 9.3.12 Input Current Limit Programming by External Components (ILIM)
      13. 9.3.13 Charge Current Programming by External Components (ISET)
      14. 9.3.14 Safety Timer
      15. 9.3.15 External NTC Monitoring (TS)
      16. 9.3.16 Thermal Protection
      17. 9.3.17 Typical Application Power Dissipation
      18. 9.3.18 Status Indicators ( PG and INT)
      19. 9.3.19 Chip Disable ( CD)
      20. 9.3.20 Buck (PWM) Output
      21. 9.3.21 Load Switch / LDO Output and Control
      22. 9.3.22 Manual Reset Timer and Reset Output ( MR and RESET)
    4. 9.4 Device Functional Modes
    5. 9.5 Programming
      1. 9.5.1 Serial Interface Description
      2. 9.5.2 F/S Mode Protocol
    6. 9.6 Register Maps
      1. 9.6.1  Status and Ship Mode Control Register
      2. 9.6.2  Faults and Faults Mask Register
      3. 9.6.3  TS Control and Faults Masks Register
      4. 9.6.4  Fast Charge Control Register
      5. 9.6.5  Termination/Pre-Charge Register
      6. 9.6.6  Battery Voltage Control Register
      7. 9.6.7  SYS VOUT Control Register
      8. 9.6.8  Load Switch and LDO Control Register
      9. 9.6.9  Push-button Control Register
      10. 9.6.10 ILIM and Battery UVLO Control Register
      11. 9.6.11 Voltage Based Battery Monitor Register
      12. 9.6.12 VIN_DPM and Timers Register
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 Default Settings
        2. 10.2.2.2 Choose the Correct Inductance and Capacitance
        3. 10.2.2.3 Calculations
          1. 10.2.2.3.1 Program the Fast Charge Current (ISET)
          2. 10.2.2.3.2 Program the Input Current Limit (ILIM)
          3. 10.2.2.3.3 Program the Pre-charge/termination Threshold (IPRETERM)
          4. 10.2.2.3.4 TS Resistors (TS)
      3. 10.2.3 Application Performance Curves
        1. 10.2.3.1 Charger Curves
        2. 10.2.3.2 SYS Output Curves
        3. 10.2.3.3 Load Switch and LDO Curves
        4. 10.2.3.4 LS/LDO Output Curves
        5. 10.2.3.5 Timing Waveforms Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Device Support
      1. 13.1.1 Third-Party Products Disclaimer
    2. 13.2 Receiving Notification of Documentation Updates
    3. 13.3 サポート・リソース
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Device Functional Modes

Table 9-10 Modes and Functions
FUNCTION READY (PRIOR TO I2C) AND AFTER RESET HOST MODE READY (AFTER I2C) CHARGE SHIP MODE HIGH_Z ACTIVE BATTERY
VOVP Yes Yes Yes No No No
VUVLO Yes Yes Yes Yes Yes Yes
VBATUVLO Yes Yes Yes No Yes Yes
VINDPM Default or registers Default or registers If enabled No No No
SYS Default or registers Default or registers If enabled No If enabled If enabled
LS/LDO Default or registers Default or registers If enabled No If enabled If enabled
BATFET Yes Yes Yes No Yes Yes
TS Yes (VIN Valid) Yes (VIN Valid) Yes No No No
IPRETERM External Default, registers, or external Default, registers, or external No No No
ISET External Default, registers, or external Default, registers, or external No No No
ILIM External Default, registers, or external Default, registers, or external No No No
MR input Yes Yes Yes Yes Yes Yes
LSCTRL input Yes Yes Yes No Yes Yes
RESET output Yes Yes Yes No Yes Yes
INT output Yes Yes Yes No No Yes
I2C interface Yes Yes Yes No No Yes
CD input Yes Yes Yes No Yes Yes
PG output Yes Yes Yes No No If enabled
VBMON No Yes No No No Yes
Table 9-11 Fault and Status Condition Responses
FAULT or STATUS ACTIONS CHARGER BEHAVIOR SYS BEHAVIOR LS/LDO BEHAVIOR TS BEHAVIOR
VIN_OV Update VIN_OV status, Update STAT to fault, interrupt on INT, PG shown not good Disabled Enabled through BAT Enabled through BAT Disabled
VIN_UV Update VIN_UV status, interrupt on INT, PG shown not good Disabled Enabled through BAT Enabled through BAT Disabled
VIN_ILIM Update charge in progress status, interrupt on INT, input current is limited Enabled, input current limited Enabled (if enabled) Enabled (if enabled) Enabled
OVER_TEMP Disabled Disabled Disabled Disabled
BAT_UVLO Update BAT_UVLO status, Update STAT to fault, interrupt on INT Pre-charge Enabled (if enabled) and VIN Valid Enabled (if enabled) and VIN Valid Enabled if VIN Valid
SW_SYS_SHORT Enabled Current Limit Enabled (if enabled) Enabled
LS_LDO_OCP Enabled Enabled (if enabled) Current Limit Enabled
TIMER fault Update TIMER, Update STAT to fault, interrupt on INT Disabled Enabled (if enabled) Enabled (if enabled) Disabled
VINDPM Update VINDPM_STAT, Update STAT to fault, interrupt on INT Enabled, input current reduced Enabled (if enabled) Enabled (if enabled) Enabled
TS_FAULT COLD or HOT Update TS_FAULT to COLD OR HOT, Update STAT to fault, interrupt on INT Disabled Enabled (if enabled) Enabled (if enabled) Enabled
TS_FAULT COOL Update TS_FAULT to COOL, Update STAT to fault, interrupt on INT Reduce ICHG to ½ Enabled (if enabled) Enabled (if enabled) Enabled
TS_FAULT WARM Update TS_FAULT to WARM, Update STAT to fault, interrupt on INT Reduce VBATREG by 140 mV Enabled (if enabled) Enabled (if enabled) Enabled
Charge Done Update STAT to Charge Done, interrupt on INT Disabled, monitor for VBAT falling below VRCHG Enabled (if enabled) Enabled (if enabled) Enabled
GUID-EFB2B1E3-6DE7-4B12-9FAD-003DA24235BB-low.gif Figure 9-5 State Diagram
GUID-7BCFAEBD-A6D7-4532-824F-B13C260AA1F6-low.gif Figure 9-6 Change State Diagram