SNIU049 May   2021 TMP126 , TMP126-Q1 , TMP127-Q1

 

  1. 1Trademarks
  2. 2Overview
    1. 2.1 EVM Kit Contents
  3. 3EVM Hardware
    1. 3.1 TMP126EVM Board
    2. 3.2 Perforations
    3. 3.3 Subregulator
    4. 3.4 Logic Level Translator
    5. 3.5 Status LEDs
    6. 3.6 Programming Header
    7. 3.7 BSL Button
    8. 3.8 EVM Operating Conditions
  4. 4Software Download
    1. 4.1 Live Software on dev.ti.com
    2. 4.2 Offline Software
      1. 4.2.1 Download from dev.ti.com
  5. 5Software
    1. 5.1 Home Tab
    2. 5.2 Data Capture Tab
    3. 5.3 Settings Tab
    4. 5.4 Registers Tab
    5. 5.5 Collateral Tab
  6. 6Schematic, Board Layout and Bill of Materials
    1. 6.1 Schematic
    2. 6.2 Printed-Circuit Board
    3. 6.3 Bill of Materials

EVM Operating Conditions

The TMP126EVM power is supplied through the USB connector. The LDO (U1) converts the 5V from the USB to 3.3V used by the TMP126 and the MSP430. The EVM may be directly inserted into a USB port on a PC or laptop, or may be connected to the latter using an appropriate USB cable.

The controller and device sides of the EVM have different temperature limits as shown in Table 3-2. These are set by the onboard MSP430F5528 and the TMP126 ICs on the controller and breakout portions respectively.

Table 3-2 TMP114EVM Temperature Limits
BOARD SECTIONCONDITIONSTEMPERATURE RANGE

Controller Board

Recommended Operating free-air temperature, TA

-40 °C to 125 °C

Absolute Maximum junction temperature, TJ

95 °C

TMP126 Breakout

Recommended Operating free-air temperature, TA

-55 °C to 175 °C

Absolute Maxmimum junction temperature, TJ

-55 °C to 180 °C