SLUUBT5C November 2018 – June 2021 BQ40Z80
This command instructs the device to return Impedance Track related gauging information on ManufacturerBlockAccess() or ManufacturerData().
| Status | Condition |
|---|---|
| Activate | 0x007C to ManufacturerBlockAccess() or ManufacturerAccess() |
Action: Output 30 bytes of IT data values on ManufacturerBlockAccess() or ManufacturerData() in the following format: aaAAbbBBccCCddDDeeEEffFFggGGHHIiiIIjjJJkkKKllLLmmMMnnNNooOOPP where:
| Value | Description | Unit |
|---|---|---|
| AAaa | RaScale 4. Ra table scaling factor of Cell 5 | — |
| BBbb | CompRes 4. Last temperature compensated Resistance of Cell 5 | 2–10 Ω |
| CCcc | DOD0_4. Depth of discharge for Cell 5 | — |
| DDdd | DODEOC 4. Depth of discharge at end of charge of Cell 5 | — |
| EEee | QMax 4. QMax of Cell 5 | mAh |
| FFff | QMax DOD0_4. DOD0 saved to be used for next QMax update of Cell 5 The value is only valid when [VOK] = 1. | — |
| GGgg | Cell Raw DOD0_4. Raw depth of discharge for Cell 5 | — |
| HH | Cell Grid 4. Active grid point of Cell 5. This data is only valid during DISCHARGE mode when [R_DIS] = 0. If [R_DIS] = 1 or not discharging, this value is not updated. | — |
| IIii | RaScale 5. Ra table scaling factor of Cell 6 | — |
| JJjj | CompRes 5. Last temperature compensated Resistance of Cell 6 | 2–10 Ω |
| KKkk | DOD0_5. Depth of discharge for Cell 6 | — |
| LLll | DODEOC 5. Depth of discharge at end of charge of Cell 6 | — |
| MMmm | QMax 5. QMax of Cell 6 | mAh |
| NNnn | QMax DOD0_5. DOD0 saved to be used for next QMax update of Cell 6. The value is only valid when [VOK] = 1. | — |
| OOoo | Cell Raw DOD0_5. Raw depth of discharge for Cell 6 | — |
| PP | Cell Grid 5. Active grid point of Cell 6. This data is only valid during DISCHARGE mode when [R_DIS] = 0. If [R_DIS] = 1 or not discharging, this value is not updated. | — |