SLUUCF2C January 2021 – May 2022 BQ769142
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CMDF | HWMX | VSSF | VREF | LFOF | IRMF | DRMF | OTPF |
Description: Saved Permanent Failure Status D
| Bit | Field | Description |
|---|---|---|
| 7 | CMDF | 0 = Commanded Permanent Fail did not occur 1 = Commanded Permanent Fail occurred |
| 6 | HWMX | 0 = Protection Comparator MUX Permanent Fail did not occur 1 = Protection Comparator MUX Permanent Fail occurred |
| 5 | VSSF | 0 = VSS Permanent Fail did not occur 1 = VSS Permanent Fail occurred |
| 4 | VREF | 0 = VREF Permanent Fail did not occur 1 = VREF Permanent Fail occurred |
| 3 | LFOF | 0 = Low Frequency Oscillator Monitor Permanent Fail did not occur 1 = Low Frequency Oscillator Monitor Permanent Fail occurred |
| 2 | IRMF | 0 = Instruction ROM Permanent Fail did not occur 1 = Instruction ROM Permanent Fail occurred |
| 1 | DRMF | 0 = Data ROM Permanent Fail did not occur 1 = Data ROM Permanent Fail occurred |
| 0 | OTPF | 0 = OTP Memory Permanent Fail did not occur 1 = OTP Memory Permanent Fail occurred |