SLVK033A February   2019  – August 2021 INA240-SEP

 

  1.   Trademarks
  2. 1Device Information
    1. 1.1 Device Details
  3. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Biased
    4. 2.4 Test Configuration and Condition
  4. 3Tested Parameters
  5. 4Total Ionizing Dose (RHA) Characterization Test Results
    1. 4.1 Offset Voltage
    2. 4.2 Gain Error
  6.   A Total Ionizing Dose HDR Report
  7.   B Revision History

Gain Error

Gain Error showed little variation at 30 krad(Si) but is still within data sheet limits. The graphs below show the minimum, average, and maximum data post irradiation for each dose level.

GUID-FE64D574-088D-4BE7-8E05-72F08E6EBF67-low.png Figure 4-2 Radiation Exposure Effect on Gain Error