SLVS350K October 2002 – June 2025 TPS795
PRODUCTION DATA
Using the thermal metrics ΨJT and ΨJB, as shown in Thermal Information, the junction temperature can be estimated with corresponding formulas (given in Equation 7). For backwards compatibility, an older θJC,Top parameter is also listed.

where
Both TT and TB can be measured on actual application boards using a thermo‐gun (an infrared thermometer).
For more information about measuring TT and TB, see the Using New Thermal Metrics application note, available for download at www.ti.com.
As shown in Figure 7-7, the new thermal metrics (ΨJT and ΨJB) have little dependency on board size. That is, using ΨJT or ΨJB with Equation 7 is a good way to estimate TJ by simply measuring TT or TB, regardless of the application board size.
Figure 7-7 ΨJT and ΨJB vs Board SizeFor a more detailed discussion of why TI does not recommend using θJC(top) to determine thermal characteristics, see the Using New Thermal Metrics application note, available at www.ti.com.
For further information, see the IC Package Thermal Metrics application note, also available on the TI website.
Figure 7-8 Measuring Point for TT and TB