SLVSHN2A August 2024 – February 2026 DRV8962-Q1
PRODUCTION DATA
The total power dissipation in each half-bridge can be calculated as:
PHB = PHS + PLS = [RDS(ON) × IL2] + [((2 x VD x tD) + (VM x tRF)) x IL x fPWM]
Where
Total power dissipation in the DRV8962-Q1 is:
PTOT = n × PHB + PQ
Where n is the number of half-bridges switching at the same time, and PQ is the quiescent power loss.
For this example, assume:
When the VCC pin is connected to an external power supply, the quiescent current is 4 mA, and therefore PQ will be (24 V x 4 mA) = 96 mW.
PHB = [53 mΩ × 3 2] + [((2 x 1 V x 300 ns) + (24 V x 70 ns)) x 3 A x 20 KHz] = 0.614 W
PTOT = (4 x 0.614) + 0.096 = 2.552 W