The data was tested on the EVM, with L1 changed to 4.7 uH. The EVM was configured for 1-MHz operation and 5 VOUT, and was measured at 12 VIN and a 2.5-A load.

GUID-20221215-SS0I-VWRZ-GMCM-HSMXBZJTK30L-low.png Figure 5-1 CISPR11/32 Conducted Scan

The data was tested on the EVM, with L1 changed to 4.7 uH. The EVM was configured for 1-MHz operation and 5 VOUT, and was measured at 24 VIN and a 2.5-A load.

GUID-20221215-SS0I-SDZN-TQX3-NLBBC5MK41MG-low.png Figure 5-2 CISPR11/32 Conducted Scan

12 VIN, 2.2 MHz, 2-A load (continuous)

GUID-20221216-SS0I-ZQBW-TXK5-CHX4DGJ9JT7M-low.png Figure 5-3 IR Top Case Measurement

12 VIN, 1 MHz, 2-A load (continuous)

GUID-20221216-SS0I-ZKPD-NWR6-3F4DCX4V16PH-low.png Figure 5-4 IR Top Case Measurement

12 VIN, 500 kHz, 2-A load (continuous)

GUID-20221216-SS0I-RDQS-KQXD-BJ3HLK2RKXNK-low.png Figure 5-5 IR Top Case Measurement

24 VIN, 2.2 MHz, 2-A load (continuous)

GUID-20221216-SS0I-RKWQ-FVQF-9TTPH0RPG8TF-low.png Figure 5-6 IR Top Case Measurement

24 VIN, 1 MHz, 2-A load (continuous)

GUID-20221216-SS0I-ZNLS-JBPW-LLJ4JDV1HHQ2-low.png Figure 5-7 IR Top Case Measurement

24 VIN, 500 kHz, 2-A load (continuous)

GUID-20221216-SS0I-MRQR-FN1K-WFTJVWB80Q9R-low.png Figure 5-8 IR Top Case Measurement