To setup the software configuration,
follow the instructions below.
- Open the Application Customization Tool and select
Configuration Index 1 or 3 for Question 1 (A figure with a BQ block
included).
- Fill out the questionnaire
from Q2 to Q10. For more details on each question configuration, refer to
Section 3.4.3. All the questions must be filled out to flash or export.
- Questions 11 through 17
pertain to Battery Charger (BQ) settings.
- For Question 11, select
BQ25756.
- For Question 12, select the
INDPM configuration for the BQ25756.
- For example, if the
user selects 5% - INDPM is set to 5% above the negotiated PD
Contract Current and TPS26750 negotiates a PD contract at
3A, then the INDPM is set to 3.15A.
- This questionnaire
configures register 0x06 - IAC_DPM of the BQ25756.
- For Question 13, select the
VINDPM configuration for the BQ25756.
- For example, if the
user selects 5% - VINDPM is set to 5% below the negotiated PD
Contract Voltage and TPS26750 negotiates a PD contract at
5V, the VINDPM is set to 4.75V.
- This questionnaire
configures register 0x08 - VAC_DPM of the BQ25756.
- For question 14, enter the FB
Voltage Regulation Limit in units of Voltage (1.504V through 1.566V,
2mV/bit).
- This questionnaire
configures register 0x00 - VFB_REG of the BQ25756.
- For question 15, enter the
Charge Current Limit in units of Ampere (0.4A through 20A, 50mA/bit)
- This questionnaire
configures register 0x02 - ICHG_REG of the BQ25756.
- For question 16, enter the
Charge Termination Current Limit in units of Ampere (0.25A through 10A,
50mA/bit).
- This questionnaire
configures register 0x12 - ITERM of the BQ25756.
- For question 17, enter the
Precharge Current Limit in units of Ampere (0.25A through 10A, 50mA/bit).
- This questionnaire
configures register 0x10 - IPRECHG of the BQ25756.
- For flashing the