SLYS055F July   2025  – March 2026 TMAG5134

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Magnetic Characteristics
    7. 6.7 Typical Characteristics
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 SOT-23 Magnetic Flux Density Direction
      2. 7.3.2 Omnipolar Output
      3. 7.3.3 X1LGA Magnetic Flux Direction
      4. 7.3.4 Dual-Unipolar Output
      5. 7.3.5 Sampling Rate
      6. 7.3.6 Output Logic Tables
      7. 7.3.7 Hall Element Location
    4. 7.4 Device Functional Modes
  9. 8 Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Performance Plots
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. 9 Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Output Logic Tables

Table 7-1 and Table 7-2 shows the output status during different external magnetic field conditions (BEXT). When the BEXT is between BRP and BOP, the TMAG5134 output will retain the previous state.

Table 7-1 TMAG5134 Active-Low Output Logic Table
Field Condition Unipolar Omnipolar
OUT1 OUT2 OUT
BEXT ≤ -BOP H L L
-BRP ≤ BEXT ≤ BRP H H H
BRP ≤ BEXT L H L
|BRP| ≤ BEXT ≤ |BOP| Retain Previous State
Table 7-2 TMAG5134 Active-High Output Logic Table
Field Condition Unipolar Omnipolar
OUT1 OUT2 OUT
BEXT ≤ -BOP L H H
-BRP ≤ BEXT ≤ BRP L L L
BRP ≤ BEXT H L H
|BRP| ≤ BEXT ≤ |BOP| Retain Previous State