SLYS055F July 2025 – March 2026 TMAG5134
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| TMAG5134Axx 1mT | ||||||
| BOP | Magnetic threshold operate point | TA = 25°C | ±0.75 | ±1 | ±1.25 | mT |
| TA = –40°C to 85°C | ±0.7 | ±1 | ±1.3 | |||
| TA = –40°C to 125°C | ±0.7 | ±1 | ±1.3 | |||
| BRP | Magnetic release operate point | TA = 25°C | ±0.33 | ±0.6 | ±0.87 | mT |
| TA = –40°C to 85°C | ±0.3 | ±0.6 | ±0.9 | |||
| TA = –40°C to 125°C | ±0.3 | ±0.6 | ±0.9 | |||
| BHYS | Magnetic hysteresis: |BOP – BRP| | TA = 25°C | 0.18 | 0.4 | mT | |
| TA = –40°C to 85°C | 0.14 | 0.4 | ||||
| TA = –40°C to 125°C | 0.12 | 0.4 | ||||
| TMAG5134Bxx 1.3mT | ||||||
| BOP | Magnetic threshold operate point | TA = 25°C | ±1.05 | ±1.3 | ±1.55 | mT |
| TA = –40°C to 85°C | ±0.97 | ±1.3 | ±1.63 | |||
| TA = –40°C to 125°C | ±0.93 | ±1.3 | ±1.67 | |||
| BRP | Magnetic release operate point | TA = 25°C | ±0.65 | ±0.9 | ±1.15 | mT |
| TA = –40°C to 85°C | ±0.54 | ±0.9 | ±1.26 | |||
| TA = –40°C to 125°C | ±0.43 | ±0.9 | ±1.37 | |||
| BHYS | Magnetic hysteresis: |BOP – BRP| | TA = 25°C | 0.15 | 0.4 | mT | |
| TA = –40°C to 85°C | 0.13 | 0.4 | ||||
| TA = –40°C to 125°C | 0.12 | 0.4 | ||||
| TMAG5134Cxx 1.5mT | ||||||
| BOP | Magnetic threshold operate point | TA = 25°C | ±1.20 | ±1.5 | ±1.80 | mT |
| TA = –40°C to 85°C | ±1.15 | ±1.5 | ±1.85 | |||
| TA = –40°C to 125°C | ±1.10 | ±1.5 | ±1.90 | |||
| BRP | Magnetic release operate point | TA = 25°C | ±0.80 | ±1.1 | ±1.40 | mT |
| TA = –40°C to 85°C | ±0.75 | ±1.1 | ±1.45 | |||
| TA = –40°C to 125°C | ±0.69 | ±1.1 | ±1.5 | |||
| BHYS | Magnetic hysteresis: |BOP – BRP| | TA = 25°C | 0.17 | 0.4 | mT | |
| TA = –40°C to 85°C | 0.14 | 0.4 | ||||
| TA = –40°C to 125°C | 0.12 | 0.4 | ||||
| TMAG5134Exx 2mT | ||||||
| BOP | Magnetic threshold operate point | TA = 25°C | ±1.6 | ±2 | ±2.4 | mT |
| TA = –40°C to 85°C | ±1.55 | ±2 | ±2.45 | |||
| TA = –40°C to 125°C | ±1.45 | ±2 | ±2.55 | |||
| BRP | Magnetic release operate point | TA = 25°C | ±1.25 | ±1.6 | ±1.95 | mT |
| TA = –40°C to 85°C | ±1.10 | ±1.6 | ±2.10 | |||
| TA = –40°C to 125°C | ±1.00 | ±1.6 | ±2.2 | |||
| BHYS | Magnetic hysteresis: |BOP – BRP| | TA = 25°C | 0.17 | 0.4 | mT | |
| TA = –40°C to 85°C | 0.14 | 0.4 | ||||
| TA = –40°C to 125°C | 0.12 | 0.4 | ||||
| TMAG5134Hxx 0.9mT | ||||||
| BOP | Magnetic threshold operate point | TA = 25°C | ±0.65 | ±0.9 | ±1.15 | mT |
| TA = –40°C to 85°C | ±0.6 | ±0.9 | ±1.2 | |||
| TA = –40°C to 125°C | ±0.6 | ±0.9 | ±1.25 | |||
| BRP | Magnetic release operate point | TA = 25°C | ±0.3 | ±0.5 | ±0.75 | mT |
| TA = –40°C to 85°C | ±0.2 | ±0.5 | ±0.8 | |||
| TA = –40°C to 125°C | ±0.2 | ±0.5 | ±0.85 | |||
| BHYS | Magnetic hysteresis: |BOP – BRP| | TA = 25°C | 0.18 | 0.4 | mT | |
| TA = –40°C to 85°C | 0.14 | 0.4 | ||||
| TA = –40°C to 125°C | 0.12 | 0.4 | ||||