SLYY242 November 2024
Defined functional safety standards help determine whether or not a system is safe. The most popular standards are IEC 61508 and International Organization for Standardization (ISO) 13849. Both standards look at the failure mode diagnostic coverage or safe failure fraction, as well as the hardware fault tolerance, to determine the safety integrity level (SIL) or performance level (PL) that a system meets. Table 2 summarizes these ratings.
| Hardware fault tolerance (HFT) | Category | |||||||
|---|---|---|---|---|---|---|---|---|
| IEC 61508 | ISO 13849 | |||||||
| 0 | 1 | 2 | SFF | DC | 1 | 2 | 3 | 4 |
| - | SIL1 | SIL2 | <60% | None | ||||
| SIL1 | SIL2 | SIL3 | 60% to <90% | Low | c | c | d | |
| SIL2 | SIL3 | SIL4 | 90% to <99% | Medium | d | e | ||
| SIL4 | SIL4 | ≤99% | High | e | ||||
| Type B | ||||||||
Using Table 2 as a guide, you can see that there are multiple ways to obtain each IEC 61508 SIL or ISO 13849 PL. By designing a system with the appropriate safe failure fraction or diagnostic coverage and hardware fault tolerance, you can reach one of these levels. In particular, monitoring the voltage of your power supply can increase your diagnostic coverage. The implementation of voltage monitoring can also increase your hardware fault tolerance.
Table 3 provides more information on each of these safety parameters.
As you can see, you must account for not just the number of failures possible but the likelihood of failures occurring. You can also see that by increasing your diagnostic coverage or safe failure fraction, you can move up in SIL or PL without changing your hardware fault tolerance, and vice versa. Voltage monitoring is an essential aspect of determining the diagnostic coverage or safe failure fraction of your system and reducing your residual FIT of the system solution.
| Measurement | Definition |
|---|---|
| Hardware fault tolerance | Minimum number of tolerable failures for a system while also retaining safety functionality |
| Safe failure fraction |
Equation 1.
|
| Diagnostic coverage |
Equation 2.
|
| SIL | Functional safety rating system |