SNAS264D April 2006 – February 2024 LM94
PRODUCTION DATA
The PWM output can operate at lower frequencies, instead of the default 22.5 kHz. The lower frequencies can be enabled through the PWMx Control 4 registers. Operating in the lower frequency mode, enables an alternate mapping of step numbers to duty cycle. This effects the auto fan control and all LM94 registers that describe a duty cycle using a 4-bit value. This alternate mapping can also be enable when using the default 22.5 kHz PWM frequency.
The alternate LUT PWM duty cycle mapping is listed in the following table:
| 4-Bit Value | LUT Step | Alternate LUT Duty Cycle |
|---|---|---|
| 0h | 0% | |
| 1h | 1 | 25.00% |
| 2h | 2 | 28.57% |
| 3h | 3 | 32.14% |
| 4h | 4 | 35.71% |
| 5h | 5 | 39.29% |
| 6h | 6 | 42.86% |
| 7h | 7 | 46.43% |
| 8h | 8 | 50.00% |
| 9h | 9 | 53.57% |
| Ah | 10 | 57.14% |
| Bh | 11 | 71.43% |
| Ch | 12 | 85.71% |
| Dh | 13 | 100.00% |
| Eh | — | Reserved |
| Fh | — | Reserved |