SCHS319B november   2002  – august 2023 CD74ACT14

PRODUCTION DATA  

  1.   1
  2. 1Features
  3. 2Description
  4. 3Revision History
  5. 4Pin Configuration and Functions
  6. 5Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
    7. 5.7 Operating Characteristics
  7. 6Parameter Measurement Information
  8. 7Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
  9. 8Device and Documentation Support
    1. 8.1 Documentation Support (Analog)
      1. 8.1.1 Related Documentation
    2. 8.2 Receiving Notification of Documentation Updates
    3. 8.3 Support Resources
    4. 8.4 Trademarks
    5. 8.5 Electrostatic Discharge Caution
    6. 8.6 Glossary
  10. 9Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • D|14
  • N|14
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VCC TA = 25°C − 55°C TO 125°C − 40°C TO 85°C UNIT
MIN MAX MIN MAX MIN MAX
VT+
Positive-going threshold
5 V 1.4 2 1.4 2 1.4 2 V
VT−
Negative-going threshold
5 V 0.8 1.3 0.8 1.3 0.8 1.3 V
∆VT
Hysteresis (VT+ − VT−)
5 V 0.4 0.4 0.4 V
VOH VI = V T+ IOH = –50 µA 4.5 V 4.4 4.4 4.4 V
IOH = −24 mA 4.5 V 3.94 3.7 3.8
IOH = −50 mA(1) 5.5 V 3.85
IOH = −75 mA(1) 5.5 V 3.85
VOL VI = VT− IOL = 50 µA(1) 4.5 V 0.1 0.1 0.1 V
IOL = 24 mA(1) 4.5 V 0.36 0.5 0.44
IOL = 50 mA(1) 5.5 V 1.65
IOL = 75 mA(1) 5.5 V 1.65
II VI = VCC or GND 5.5 V ±0.1 ±1 ±1 µA
ICC VI = VCC or GND, IO = 0 5.5 V 4 80 40 µA
∆ICC(2) VI = VCC − 2.1 V 4.5 V to 5.5 V 2.4 3 2.8 mA
Ci 10 10 10 pF
Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive capability at 125°C.
Additional quiescent supply current per input pin, TTL inputs high, 1 unit load.
Table 5-1 Act Input Load Table
INPUT UNIT LOAD
A 0.21
  1. Unit load is ∆ICC limit specified in electrical characteristics table (e.g., 2.4 mA at 25°C).