SCLS419G june   1998  – may 2023 SN74AHCT174

PRODMIX  

  1.   1
  2. 1Features
  3. 2Applications
  4. 3Description
  5. 4Revision History
  6. 5Pin Configuration and Functions
  7. 6Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Electrical Characteristics
    5. 6.5 Timing Requirements
    6. 6.6 Switching Characteristics
    7. 6.7 Noise Characteristics
    8. 6.8 Operating Characteristics
  8. 7Parameter Measurement Information
  9. 8Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Device Functional Modes

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DB|16
  • PW|16
  • NS|16
  • N|16
  • D|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VCC TA = 25 °C SN74AHCT174 UNIT
MIN TYP MAX MIN MAX
VOH IOH = -50 μA 4.5 V 4.4 4.5 4.4 V
IOH = -8 mA 3.94 3.8
VOL IOL = 50 μA 4.5 V 0.1 0.1 V
IOL = 8 mA 0.36 0.44
II VI = 5.5 V or GND 0 V to 5.5 V ±0.1 ±1 μA
ICC VI = VCC or GND, IO = 0 5.5 V 4 40 μA
ΔICC (1) One input at 3.4 V, Other inputs at VCC or GND 5.5 V 1.35 1.5 μA
Ci VI = VCC or GND 5 V 2 10 10 pF
This is the increase in supply current for each input at one of the specified TTL voltage levels rather than 0 V or VCC.