SCDS384A September   2018  – December 2018 TMUX6119

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
    1.     Device Images
      1.      Simplified Schematic
  4. Revision History
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Thermal Information
    4. 6.4 Recommended Operating Conditions
    5. 6.5 Electrical Characteristics (Dual Supplies: ±15 V)
    6. 6.6 Switching Characteristics (Dual Supplies: ±15 V)
    7. 6.7 Electrical Characteristics (Single Supply: 12 V)
    8. 6.8 Switching Characteristics (Single Supply: 12 V)
    9. 6.9 Typical Characteristics
  7. Parameter Measurement Information
    1. 7.1 Truth Tables
  8. Detailed Description
    1. 8.1 Overview
      1. 8.1.1  On-Resistance
      2. 8.1.2  Off-Leakage Current
      3. 8.1.3  On-Leakage Current
      4. 8.1.4  Transition Time
      5. 8.1.5  Break-Before-Make Delay
      6. 8.1.6  Enable Turn-On and Enable Turn-Off Time
      7. 8.1.7  Charge Injection
      8. 8.1.8  Off Isolation
      9. 8.1.9  Channel-to-Channel Crosstalk
      10. 8.1.10 Bandwidth
      11. 8.1.11 THD + Noise
      12. 8.1.12 AC Power Supply Rejection Ratio (AC PSRR)
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Ultra-low Leakage Current
      2. 8.3.2 Ultra-low Charge Injection
      3. 8.3.3 Bidirectional and Rail-to-Rail Operation
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Community Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Switching Characteristics (Single Supply: 12 V)

at TA = 25°C, VDD = 12 V, and VSS = 0 V (unless otherwise noted)(1)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
tON Enable turn-on time VS = 8 V, RL = 300 Ω , CL = 35 pF 73 91 ns
VS = 8 V, RL = 300 Ω , CL = 35 pF, TA = –40°C to +85°C   119 ns
VS = 8 V, RL = 300 Ω , CL = 35 pF, TA = –40°C to +125°C   130 ns
tOFF Enable turn-off time VS = 8 V, RL = 300 Ω , CL = 35 pF 60 69 ns
VS = 8 V, RL = 300 Ω , CL = 35 pF, TA = –40°C to +85°C 82 ns
VS = 8 V, RL = 300 Ω , CL = 35 pF, TA = –40°C to +125°C   88 ns
tTRAN Transition time VS = 8 V, RL = 300 Ω , CL = 35 pF 73 93 ns
VS = 8 V, RL = 300 Ω , CL = 35 pF, TA = –40°C to +85°C   104 ns
VS = 8 V, RL = 300 Ω , CL = 35 pF, TA = –40°C to +125°C   112 ns
tBBM Break-before-make time delay VS = 8 V, RL = 300 Ω , CL = 35 pF, TA = –40°C to +125°C 10 45 ns
QJ Charge injection VS = 6 V, RS = 0 Ω , CL = 1 nF   0.1 pC
OISO Off-isolation RL = 50 Ω , CL = 5 pF, f = 1 MHz -85 dB
XTALK Channel-to-channel crosstalk RL = 50 Ω , CL = 5 pF, f = 1 MHz –100 dB
IL Insertion loss RL  =  50 Ω , CL = 5 pF, f =  1 MHz -15 dB
ACPSRR AC Power Supply Rejection Ratio R= 10 kΩ , CL = 5 pF, VPP= 0.62 V, f= 1 MHz –55 dB
BW -3dB Bandwidth RL  =  50 Ω , CL = 5 pF 440 MHz
CIN Digital input capacitance VIN = 0 V or VDD 1   pF
CS(OFF) Source off-capacitance VS = 6 V, f = 1 MHz 2 2.9 pF
CD(OFF) Drain off-capacitance VS = 6 V, f = 1 MHz 4.9 5.3 pF
CS(ON), CD(ON) Source and drain on-capacitance VS = 6 V, f = 1 MHz 7.4 8.9 pF
Specified by design; not subject to production testing.