JAJSQP4 February   2024 ADS1288

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Requirements: 1.65V ≤ IOVDD ≤ 1.95V and 2.7V ≤ IOVDD ≤ 3.6V
    7. 5.7 Switching Characteristics: 1.65V ≤ IOVDD ≤ 1.95V and 2.7V ≤ IOVDD ≤ 3.6V
    8. 5.8 Timing Diagrams
    9. 5.9 Typical Characteristics
  7. Parameter Measurement Information
    1. 6.1 Noise Performance
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Analog Input
      2. 7.3.2 PGA and Buffer
        1. 7.3.2.1 Programmable Gain Amplifier (PGA)
        2. 7.3.2.2 Buffer Operation (PGA Bypass)
      3. 7.3.3 Voltage Reference Input
      4. 7.3.4 IOVDD Power Supply
      5. 7.3.5 Modulator
        1. 7.3.5.1 Modulator Overdrive
      6. 7.3.6 Digital Filter
        1. 7.3.6.1 Sinc Filter Section
        2. 7.3.6.2 FIR Filter Section
        3. 7.3.6.3 Group Delay and Step Response
          1. 7.3.6.3.1 Linear Phase Response
          2. 7.3.6.3.2 Minimum Phase Response
        4. 7.3.6.4 HPF Stage
      7. 7.3.7 Clock Input
      8. 7.3.8 GPIO
    4. 7.4 Device Functional Modes
      1. 7.4.1 Power-Down Mode
      2. 7.4.2 Reset
      3. 7.4.3 Synchronization
        1. 7.4.3.1 Pulse-Sync Mode
        2. 7.4.3.2 Continuous-Sync Mode
      4. 7.4.4 Sample Rate Converter
      5. 7.4.5 Offset and Gain Calibration
        1. 7.4.5.1 OFFSET Register
        2. 7.4.5.2 GAIN Register
        3. 7.4.5.3 Calibration Procedure
    5. 7.5 Programming
      1. 7.5.1 Serial Interface
        1. 7.5.1.1 Chip Select (CS)
        2. 7.5.1.2 Serial Clock (SCLK)
        3. 7.5.1.3 Data Input (DIN)
        4. 7.5.1.4 Data Output (DOUT)
        5. 7.5.1.5 Data Ready (DRDY)
      2. 7.5.2 Conversion Data Format
      3. 7.5.3 Commands
        1. 7.5.3.1  Single Byte Command
        2. 7.5.3.2  WAKEUP: Wake Command
        3. 7.5.3.3  STANDBY: Software Power-Down Command
        4. 7.5.3.4  SYNC: Synchronize Command
        5. 7.5.3.5  RESET: Reset Command
        6. 7.5.3.6  Read Data Direct
        7. 7.5.3.7  RDATA: Read Conversion Data Command
        8. 7.5.3.8  RREG: Read Register Command
        9. 7.5.3.9  WREG: Write Register Command
        10. 7.5.3.10 OFSCAL: Offset Calibration Command
        11. 7.5.3.11 GANCAL: Gain Calibration Command
  9. Register Map
    1. 8.1 Register Descriptions
      1. 8.1.1 ID/SYNC: Device ID, SYNC Register (Address = 00h) [Reset = xxxx0010b]
      2. 8.1.2 CONFIG0: Configuration Register 0 (Address = 01h) [Reset = 92h]
      3. 8.1.3 CONFIG1: Configuration Register 1 (Address = 02h) [Reset = 10h]
      4. 8.1.4 HPF0, HPF1: High-Pass Filter Registers (Address = 03h, 04h) [Reset = 32h, 03h]
      5. 8.1.5 OFFSET0, OFFSET1, OFFSET2: Offset Calibration Registers (Address = 05h, 06h, 07h) [Reset = 00h, 00h, 00h]
      6. 8.1.6 GAIN0, GAIN1, GAIN2: Gain Calibration Registers (Address = 08h, 09h, 0Ah) [Reset = 00h, 00h, 40h]
      7. 8.1.7 GPIO: Digital Input/Output Register (Address = 0Bh) [Reset = 000xx000b]
      8. 8.1.8 SRC0, SRC1: Sample Rate Converter Registers (Address = 0Ch, 0Dh) [Reset = 00h, 80h]
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
    3. 9.3 Power Supply Recommendations
      1. 9.3.1 Analog Power Supplies
      2. 9.3.2 Digital Power Supply
      3. 9.3.3 Grounds
      4. 9.3.4 Thermal Pad
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 ドキュメントの更新通知を受け取る方法
    2. 10.2 サポート・リソース
    3. 10.3 Trademarks
    4. 10.4 静電気放電に関する注意事項
    5. 10.5 用語集
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

FIR Filter Section

The second section of the digital filter is a multistage, FIR low-pass filter. Partially filtered data from the sinc filter are input to the FIR filter. The FIR filter determines the final frequency and phase response of the output data. Figure 7-14 shows that the FIR filter consists of four stages.

GUID-20201019-CA0I-J84Q-H3LZ-Q7HKMPFJHDCC-low.svg Figure 7-14 FIR Filter

The first two FIR stages are half-band filters with decimation = 2 in each stage. The third and fourth FIR stages determine the final frequency and phase response. Decimation is 4 and 2, in stages three and four. The total decimation ratio of the FIR filter is 32. Different filter coefficient sets in stage 3 and 4 determine linear or minimum phase filter response. The phase response is selected by the PHASE bit of the CONFIG0 register. Table 7-4 lists the combined decimation ratio of the sinc and FIR filter stages and the corresponding FIR filter data rate.

Table 7-4 FIR Filter Data Rate
DR[2:0] BITS COMBINED DECIMATION RATIO DATA RATE (SPS)
000 8192 125
001 4096 250
010 2048 500
011 1024 1000
100 512 2000

Table 7-5 lists the FIR filter coefficients and the data scaling for the linear and minimum phase coefficients.

Table 7-5 FIR Filter Coefficients
COEFFICIENT STAGE 1 STAGE 2 STAGE 3 STAGE 4
SCALE = 1/512 SCALE = 1/8388608 SCALE = 1/134217728 SCALE = 1/134217728
LINEAR PHASE LINEAR PHASE LINEAR PHASE MINIMUM PHASE LINEAR PHASE MINIMUM PHASE
b0 3 –10944 0 819 –132 11767
b1 0 0 0 8211 –432 133882
b2 –25 103807 –73 44880 –75 769961
b3 0 0 –874 174712 2481 2940447
b4 150 –507903 –4648 536821 6692 8262605
b5 256 0 –16147 1372637 7419 17902757
b6 150 2512192 –41280 3012996 –266 30428735
b7 0 4194304 –80934 5788605 –10663 40215494
b8 –25 2512192 –120064 9852286 –8280 39260213
b9 0 0 –118690 14957445 10620 23325925
b10 3 –507903 –18203 20301435 22008 –1757787
b11 0 224751 24569234 348 –21028126
b12 103807 580196 26260385 –34123 –21293602
b13 0 893263 24247577 –25549 –3886901
b14 –10944 891396 18356231 33460 14396783
b15 293598 9668991 61387 16314388
b16 –987253 327749 –7546 1518875
b17 –2635779 –7171917 –94192 –12979500
b18 –3860322 –10926627 –50629 –11506007
b19 –3572512 –10379094 101135 2769794
b20 –822573 –6505618 134826 12195551
b21 4669054 –1333678 –56626 6103823
b22 12153698 2972773 –220104 –6709466
b23 19911100 5006366 –56082 –9882714
b24 25779390 4566808 263758 –353347
b25 27966862 2505652 231231 8629331
b26 25779390 126331 –215231 5597927
b27 19911100 –1496514 –430178 –4389168
b28 12153698 –1933830 34715 –7594158
b29 4669054 –1410695 580424 –428064
b30 –822573 –502731 283878 6566217
b31 –3572512 245330 –588382 4024593
b32 –3860322 565174 –693209 –3679749
b33 –2635779 492084 366118 –5572954
b34 –987253 231656 1084786 332589
b35 293598 –9196 132893 5136333
b36 891396 –125456 –1300087 2351253
b37 893263 –122207 –878642 –3357202
b38 580196 –61813 1162189 –3767666
b39 224751 –4445 1741565 1087392
b40 –18203 22484 –522533 3847821
b41 –118690 22245 –2490395 919792
b42 –120064 10775 –688945 –2918303
b43 –80934 940 2811738 –2193542
b44 –41280 –2953 2425494 1493873
b45 –16147 –2599 –2338095 2595051
b46 –4648 –1052 –4511116 –79991
b47 –874 –43 641555 –2260106
b48 –73 214 6661730 –963855
b49 0 132 2950811 1482337
b50 0 33 –8538057 1480417
b51 0 0 –10537298 –586408
b52 9818477 –1497356
b53 41426374 –168417
b54 56835776 1166800
b55 41426374 644405
b56 9818477 –675082
b57 –10537298 –806095
b58 –8538057 211391
b59 2950811 740896
b60 6661730 141976
b61 641555 –527673
b62 –4511116 –327618
b63 –2338095 278227
b64 2425494 363809
b65 2811738 –70646
b66 –688945 –304819
b67 –2490395 –63159
b68 –522533 205798
b69 1741565 124363
b70 1162189 –107173
b71 –878642 –131357
b72 –1300087 31104
b73 132893 107182
b74 1084786 15644
b75 366118 –71728
b76 –693209 –36319
b77 –588382 38331
b78 283878 38783
b79 580424 –13557
b80 34715 –31453
b81 –430178 –1230
b82 –215231 20983
b83 231231 7729
b84 263758 –11463
b85 –56082 –8791
b86 –220104 4659
b87 –56626 7126
b88 134826 –732
b89 101135 –4687
b90 –50629 –976
b91 –94192 2551
b92 –7546 1339
b93 61387 –1103
b94 33460 –1085
b95 –25549 314
b96 –34123 681
b97 348 16
b98 22008 –349
b99 10620 –96
b100 –8280 144
b101 –10663 78
b102 –266 –46
b103 7419 –42
b104 6692 9
b105 2481 16
b106 –75 0
b107 –432 –4
b108 –132 0
b109 0 0

Figure 7-15 shows the FIR pass-band frequency response to 0.375 × fDATA with ±0.003dB pass-band ripple. Figure 7-16 shows the pass-band, transition-band, and stop-band performance from 0Hz to fDATA. The filter is designed for –135dB stop-band attenuation at the Nyquist frequency.

GUID-2C631F5E-A84B-4E3D-866F-DE58E12505DC-low.gifFigure 7-15 FIR Filter Pass-Band Response
GUID-E966BE72-EAB1-40D7-B11C-A7E881DDD78D-low.gifFigure 7-16 FIR Filter Transition Band Response

As with many sampled systems, the filter response repeats at multiples of the modulator sample rate (fMOD). The filter response repeats at frequencies = N × fMOD ± f0, where N = 1, 2, and so on, and f0 = filter pass-band). If present in the signal, these frequencies fold back (or alias) into the pass-band, causing errors. A low-pass input filter at the input removes the out-of-band signal to reduce the aliasing error. For the low-frequency output signal typical of many geophones, a single-pole filter at the PGA output is sufficient to reduce aliasing of the geophone thermal noise.