JAJSJB0K August   1998  – June 2020 CD4049UB , CD4050B

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 説明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics: DC
    6. 6.6 Electrical Characteristics: AC
    7. 6.7 Typical Characteristics
  7. Parameter Measurement Information
    1. 7.1 Test Circuits
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Related Links
    3. 12.3 Receiving Notification of Documentation Updates
    4. 12.4 サポート・リソース
    5. 12.5 Trademarks
    6. 12.6 静電気放電に関する注意事項
    7. 12.7 用語集
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • PW|16
  • NS|16
  • N|16
  • DW|16
  • D|16
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics: DC

PARAMETERTEST CONDITIONSMINTYPMAXUNIT
IDD(Max)Quiescent device currentVIN = 0 or 5 V, VCC = 5 VTA = –55 °C1µA
TA = –40 °C1
TA = 25 °C0.021
TA = 85 °C30
TA = 125 °C30
VIN = 0 or 10 V, VCC = 10 VTA = –55 °C2
TA = –40 °C2
TA = 25 °C0.022
TA = 85 °C60
TA = 125 °C60
VIN = 0 or 15 V, VCC = 4 VTA = –55 °C4
TA = –40 °C4
TA = 25 °C0.024
TA = 85 °C120
TA = 125 °C120
VIN = 0 or 20 V, VCC = 20 VTA = –55 °C20
TA = –40 °C20
TA = 25 °C0.0420
TA = 85 °C600
TA = 125 °C600
IOL(Min)Output low (sink) currentVOUT = 0.4 V, VIN = 0 or 5 V, VCC = 4.5 VTA = –55 °C3.3mA
TA = –40 °C3.1
TA = 25 °C2.65.2
TA = 85 °C2.1
TA = 125 °C1.8
VOUT = 0.4 V, VIN = 0 or 5 V, VCC = 5 VTA = –55 °C4
TA = –40 °C3.8
TA = 25 °C3.26.4
TA = 85 °C2.9
TA = 125 °C2.4
VOUT = 0.5 V, VIN = 0 or 10 V, VCC = 10 VTA = –55 °C10
TA = –40 °C9.6
TA = 25 °C816
TA = 85 °C6.6
TA = 125 °C5.6
VOUT = 1.5 V, VIN = 0 or 15 V, VCC = 15 VTA = –55 °C26
TA = –40 °C25
TA = 25 °C2448
TA = 85 °C20
TA = 125 °C18
IOH(Min)Output high (source) currentVOUT = 4.6 V, VIN = 0 or 5 V, VCC = 5 VTA = –55 °C–0.81mA
TA = –40 °C–0.73
TA = 25 °C–0.65–1.2
TA = 85 °C–0.58
TA = 125 °C–0.48
VOUT = 2.5 V, VIN = 0 or 5 V, VCC = 5 VTA = –55 °C–2.6
TA = –40 °C–2.4
TA = 25 °C–2.1–3.9
TA = 85 °C–1.9
TA = 125 °C–1.55
VOUT = 9.5 V, VIN = 0 or 10 V, VCC = 10 VTA = –55 °C–2
TA = –40 °C–1.8
TA = 25 °C–1.65–3
TA = 85 °C–1.35
TA = 125 °C–1.18
VOUT = 1.3 V, VIN = 0 or 15 V, VCC = 15 VTA = –55 °C–5.2
TA = –40 °C–4.8
TA = 25 °C–4.3–8
TA = 85 °C–3.5
TA = 125 °C–3.1
VOL(Max)Out voltage low levelVIN = 0 or 5 V, VCC = 5 VTA = –55 °C0.05V
TA = –40 °C0.05
TA = 25 °C00.05
TA = 85 °C0.05
TA = 125 °C0.05
VIN = 0 or 10 V, VCC = 10 VTA = –55 °C0.05
TA = –40 °C0.05
TA = 25 °C00.05
TA = 85 °C0.05
TA = 125 °C0.05
VIN = 0 or 15 V, VCC = 15 VTA = –55 °C0.05
TA = –40 °C0.05
TA = 25 °C00.05
TA = 85 °C0.05
TA = 125 °C0.05
VOH(Min)Output voltage high levelVIN = 0 or 5 V, VCC = 5 VTA = –55 °C4.95V
TA = –40 °C4.95
TA = 25 °C4.955
TA = 85 °C4.95
TA = 125 °C4.95
VIN = 0 or 10 V, VCC = 10 VTA = –55 °C9.95
TA = –40 °C9.95
TA = 25 °C9.9510
TA = 85 °C9.95
TA = 125 °C9.95
VIN = 0 or 15 V, VCC = 15 VTA = –55 °C14.95
TA = –40 °C14.95
TA = 25 °C14.9515
TA = 85 °C14.95
TA = 125 °C14.95
VIL(Max)Input low voltage (CD4049UB)VOUT = 4.5 V, VCC = 5 V, Full temperature range1V
VOUT = 9 V, VCC = 10 V, Full temperature range2
VOUT = 13.5 V, VCC = 15 V, Full temperature range2.5
Input low voltage (CD4050B)VOUT = 0.5 V, VCC = 5 V, Full temperature range1.5
VOUT = 1 V, VCC = 10 V, Full temperature range3
VOUT = 1.5 V, VCC = 15 V, Full temperature range4
VIH(Min)Input high voltage (CD4049UB)VOUT = 0.5 V, VCC = 5 VTA = –55 °C4V
TA = –40 °C4
TA = 25 °C4
TA = 85 °C4
TA = 125 °C4
VOUT = 1 V, VCC = 10 VTA = –55 °C8
TA = –40 °C8
TA = 25 °C8
TA = 85 °C8
TA = 125 °C8
VOUT = 1.5 V, VCC = 15 VTA = –55 °C12.5
TA = –40 °C12.5
TA = 25 °C12.5
TA = 85 °C12.5
TA = 125 °C12.5
VIHInput high voltage (CD4050B)VOUT = 4.5 V, VCC = 5 VTA = –55 °C3.5V
TA = –40 °C3.5
TA = 25 °C3.5
TA = 85 °C3.5
TA = 125 °C3.5
VOUT = 9 V, VCC = 10 VTA = –55 °C7
TA = –40 °C7
TA = 25 °C7
TA = 85 °C7
TA = 125 °C7
VOUT = 13.5 V, VCC = 15 VTA = –55 °C11
TA = –40 °C11
TA = 25 °C11
TA = 85 °C11
TA = 125 °C11
IIN(Max)Input currentVIN = 0 or 18 V, VCC = 18 VTA = –55 °C±0.1µA
TA = –40 °C±0.1
TA = 25 °C±10–5±0.1
TA = 85 °C±1
TA = 125 °C±1