JAJSOR5B April   2023  – February 2024 TMAG5131-Q1

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Magnetic Characteristics
    7. 6.7 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagrams
    3. 7.3 Feature Description
      1. 7.3.1 Magnetic Flux Direction
      2. 7.3.2 Magnetic Response
      3. 7.3.3 Output Type
      4. 7.3.4 Sampling Rate
      5. 7.3.5 Hall Element Location
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Defining the Design Implementation
    2. 8.2 Typical Applications
      1. 8.2.1 Hinge
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
        3. 8.2.1.3 Application Curves
      2. 8.2.2 Head-On
        1. 8.2.2.1 Design Requirements
        2. 8.2.2.2 Detailed Design Procedure
        3. 8.2.2.3 Application Curve
      3. 8.2.3 Slide-By
        1. 8.2.3.1 Design Requirements
        2. 8.2.3.2 Detailed Design Procedure
        3. 8.2.3.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 ドキュメントの更新通知を受け取る方法
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  11. 10Revision History
  12. 11Mechanical and Packaging Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Magnetic Characteristics

for VCC = 1.65V to 5.5V, over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
A1C VERSION
BOP Magnetic operate point Temperature = 25°C  ±1.2 ±1.8 ±2.5 mT
Temperature = –40°C to 125°C ±0.9 ±1.8 ±2.7 mT
BRP Magnetic release point Temperature = 25°C  ±0.5 ±1.2 ±1.5 mT
Temperature = –40°C to 125°C ±0.3 ±1.2 ±2 mT
BHYS Magnetic hysteresis Temperature = 25°C  ±0.3 ±0.6 ±1.4 mT
Temperature = –40°C to 125°C ±0.2 ±0.6 ±1.4 mT
C1D, C7D VERSIONS
BOP Magnetic operate point Temperature = 25°C ±2.4 ±3 ±3.8 mT
Temperature = –40°C to 125°C ±2 ±3 ±4 mT
BRP Magnetic release point Temperature = 25°C ±0.8 ±1.5 ±1.9 mT
Temperature = –40°C to 125°C ±0.5 ±1.5 ±2.4 mT
BHYS Magnetic hysteresis Temperature = 25°C ±1.2 ±1.5 ±2.4 mT
Temperature = –40°C to 125°C ±1 ±1.5 ±2.5 mT
C5D VERSION
BOP Magnetic operate point Temperature = 25°C 2.4 3 3.6 mT
Temperature = –40°C to 125°C 2 3 3.8 mT
BRP Magnetic release point Temperature = 25°C 1.2 1.8 2.3 mT
Temperature = –40°C to 125°C 1 1.8 2.6 mT
BHYS Magnetic hysteresis Temperature = 25°C 0.7 1.2 1.7 mT
Temperature = –40°C to 125°C 0.6 1.2 2 mT