JAJSG04A August   2018  – June 2021 TPSM831D31

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics
    6. 6.6  References: DAC
    7. 6.7  Telemetry
    8. 6.8  Current Sense and Calibration
    9. 6.9  Logic Interface Pins: A_EN, A_PGOOD, B_EN, B_PGOOD,RESET
    10. 6.10 Protections: OVP and UVP
    11. 6.11 Typical Characteristics (VIN = 12 V)
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 DCAP+ Control
      2. 7.3.2 Setting the Load-Line (DROOP)
      3. 7.3.3 Start-Up Timing
      4. 7.3.4 Load Transitions
      5. 7.3.5 Switching Frequency
      6. 7.3.6 RESET Function
      7. 7.3.7 VID Table
    4. 7.4 Device Functional Modes
      1. 7.4.1 Continuous Conduction Mode
      2. 7.4.2 Operation With EN Signal Control
      3. 7.4.3 Operation With OPERATION Control
      4. 7.4.4 Operation With EN and OPERATION Control
    5. 7.5 Programming
      1. 7.5.1  PMBus Connections
      2. 7.5.2  PMBus Address Selection
      3. 7.5.3  Supported Commands
      4. 7.5.4  Commonly Used PMBus Commands
      5. 7.5.5  Voltage, Current, Power, and Temperature Readings
        1. 7.5.5.1 (88h) READ_VIN
        2. 7.5.5.2 (89h) READ_IIN
        3. 7.5.5.3 (8Bh) READ_VOUT
        4. 7.5.5.4 (8Ch) READ_IOUT
        5. 7.5.5.5 (8Dh) READ_TEMPERATURE_1
        6. 7.5.5.6 (96h) READ_POUT
        7. 7.5.5.7 (97h) READ_PIN
        8. 7.5.5.8 (D4h) MFR_SPECIFIC_04
      6. 7.5.6  Output Current Sense and Calibration
        1. 7.5.6.1 Reading Individual Phase Currents
          1. 7.5.6.1.1 Reading Total Current
          2. 7.5.6.1.2 51
      7. 7.5.7  Output Voltage Margin Testing
        1. 7.5.7.1 (01h) OPERATION
        2. 7.5.7.2 (26h) VOUT_MARGIN_LOW
        3. 7.5.7.3 (25h) VOUT_MARGIN_HIGH
      8. 7.5.8  Loop Compensation
        1. 7.5.8.1 (D7h) MFR_SPECIFIC_07
        2. 7.5.8.2 (28h) VOUT_DROOP
      9. 7.5.9  Converter Protection and Response
      10. 7.5.10 Output Overvoltage Protection and Response
        1. 7.5.10.1 (40h) VOUT_OV_FAULT_LIMIT
        2. 7.5.10.2 (41h) VOUT_OV_FAULT_RESPONSE
      11. 7.5.11 Maximum Allowed Output Voltage Setting
        1. 7.5.11.1 (24h) VOUT_MAX
      12. 7.5.12 Output Undervoltage Protection and Response
        1. 7.5.12.1 (44h) VOUT_UV_FAULT_LIMIT
        2. 7.5.12.2 (45h) VOUT_UV_FAULT_RESPONSE
      13. 7.5.13 Minimum Allowed Output Voltage Setting
        1. 7.5.13.1 (2Bh) VOUT_MIN
      14. 7.5.14 Output Overcurrent Protection and Response
        1. 7.5.14.1 (46h) IOUT_OC_FAULT_LIMIT
        2. 7.5.14.2 (4Ah) IOUT_OC_WARN_LIMIT
        3. 7.5.14.3 (47h) IOUT_OC_FAULT_RESPONSE
        4. 7.5.14.4 Per Phase Overcurrent Limit Thresholds
      15. 7.5.15 Input Under-Voltage Lockout (UVLO)
        1. 7.5.15.1 (35h) VIN_ON
      16. 7.5.16 Input Over-Voltage Protection and Response
        1. 7.5.16.1 (55h) VIN_OV_FAULT_LIMIT
        2. 7.5.16.2 (56h) VIN_OV_FAULT_RESPONSE
      17. 7.5.17 Input Undervoltage Protection and Response
        1. 7.5.17.1 (59h) VIN_UV_FAULT_LIMIT
        2. 7.5.17.2 (5Ah) VIN_UV_FAULT_RESPONSE
      18. 7.5.18 Input Overcurrent Protection and Response
        1. 7.5.18.1 (5Bh) IIN_OC_FAULT_LIMIT
        2. 7.5.18.2 (5Dh) IIN_OC_WARN_LIMIT
        3. 7.5.18.3 (5Ch) IIN_OC_FAULT_RESPONSE
      19. 7.5.19 Overtemperature Protection and Response
        1. 7.5.19.1 (4Fh) OT_FAULT_LIMIT
        2. 7.5.19.2 (51h) OT_WARN_LIMIT
        3. 7.5.19.3 (50h) OT_FAULT_RESPONSE
      20. 7.5.20 Dynamic Phase Shedding (DPS)
        1. 7.5.20.1 (DEh) MFR_SPECIFIC_14
        2. 7.5.20.2 (DFh) MFR_SPECIFIC_15
      21. 7.5.21 NVM Programming
      22. 7.5.22 NVM Security
        1. 7.5.22.1 (FAh) MFR_SPECIFIC_42
      23. 7.5.23 Black Box Recording
        1. 7.5.23.1 (D8h) MFR_SPECIFIC_08
      24. 7.5.24 Board Identification and Inventory Tracking
      25. 7.5.25 Status Reporting
        1. 7.5.25.1 (78h) STATUS_BYTE
        2. 7.5.25.2 (79h) STATUS_WORD
        3. 7.5.25.3 (7Ah) STATUS_VOUT
        4. 7.5.25.4 (7Bh) STATUS_IOUT
        5. 7.5.25.5 (7Ch) STATUS_INPUT
        6. 7.5.25.6 (7Dh) STATUS_TEMPERATURE
        7. 7.5.25.7 (7Eh) STATUS_CML
        8. 7.5.25.8 (80h) STATUS_MFR_SPECIFIC
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Input Capacitors
        2. 8.2.2.2 Output Capacitors
        3. 8.2.2.3 Switching Frequency
        4. 8.2.2.4 Set PMBus Address
        5. 8.2.2.5 PMBus GUI Default Values
      3. 8.2.3 Application Performance Plots
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Examples
  11. 11Device and Documentation Support
    1. 11.1 ドキュメントの更新通知を受け取る方法
    2. 11.2 サポート・リソース
    3. 11.3 Trademarks
    4. 11.4 静電気放電に関する注意事項
    5. 11.5 用語集
  12. 12Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
  • MOA|28
サーマルパッド・メカニカル・データ
発注情報

NVM Security

The MFR_SPECIFIC_42 command can be optionally used to set a password for NVM programming. To prevent a hacker from simply sending the password command with all possible passwords, the TPSM831D31 goes into a special extra-secure state when an incorrect password is received. In this state, all passwords are rejected, even the valid one. The device must be power cycled to clear this state so that another password attempt may be made. When NVM security is enabled, the TPSM831D31 will not accept writes to any command other than PAGE and PHASE, which are necessary for reading certain parameters.

Enabling NVM Security

  1. Set the NVM password. Write MFR_SPECIFIC_42 to a value other than FFFFh.
  2. Issue STORE_DEFAULT_ALL
  3. Wait 100ms for the NVM store to complete
  4. Power cycle V3P3. NVM Security will be enabled at the next power-up.

Disabling NVM Security

To disable NVM security, use the following procedure:

  1. Write the password to MFR_SPECIFIC_42 to disable NVM security. Once the correct password has been given, NVM security will be disabled, and the device will once again accept write transactions to configuration registers.

NVM security will be re-enabled at the next power-on, unless MFR_SPECIFIC_42 is set to FFFFh (NVM Security Disabled), and an NVM store operation (issue STORE_DEFAULT_ALL and wait 100 ms) is performed.

Determining Whether NVM Security is Active

Reads to the MFR_SPECIFIC_42 command returns one of three values:

  • 0000h = NVM Security is Disabled
  • 0001h = NVM Security is Enabled
  • 0002h = MFR_SPECIFIC_42 is locked due to incorrect password entry