Test Procedures

The TPS7H1101A-SP was electrically pre-tested using the production automated test equipment program. General test procedures were IAW MIL-STD-883, Method 1017 for Neutron Irradiation of TPS7H1101A-SP as listed in Table 2-1.

Table 2-1 Neutron Irradiation Conditions
Group Sample Quantity Neutron Fluence (n / cm2) Bias
A 3 1.0 × 1012 n / cm2 Unbiased
B 3 5.0 × 1012 n / cm2 Unbiased
GUID-20210519-CA0I-WJGD-ZRDS-T2HTL5BF73PK-low.jpg Figure 2-1 TPS7H1101A-SP Device