Address 0x0F Measurement Configuration

Table 5-13 Address 0x0F Measurement Configuration Register
7 6 5 4 3 2 1 0
TRES[1] TRES[0] HRES[1] HRES[0] RES MEAS_CONF[1] MEAS_CONF[0] MEAS_TRIG
Table 5-14 Address 0x0F Measurement Configuration Field Descriptions
BIT FIELD TYPE RESET DESCRIPTION
7:6 TRES[1:0] R/W 00 Temperature resolution
00: 14 bit
01: 11 bit
10: 8 bit
11: NA
5:4 HRES[1:0] R/W 00 Humidity resolution
00: 14 bit
01: 11 bit
10: 8 bit
11: NA
3 RES R/W 0 Reserved
2:1 MEAS_CONF[1:0] R/W 00 Measurement configuration
00: Humidity + Temperature
01: Temperature only
10: Humidity Only
11: NA
0 MEAS_TRIG R/W 0 Measurement trigger
0: no action
1: Start measurement
Self-cleaning bit when measurement completed