Inicio Amplificadores Amplificadores de función especial Amplificadores logarítmicos

Amplificador logarítmico de precisión y alta velocidad con corrección de corriente de oscuridad y

Detalles del producto

Input current range (min) (nA) 0.1 Input current range (max) (mA) 10 Offset voltage (input amplifiers) (max) (mV) 2000 Vs (±) (min) (V) 4.5 Vs (±) (max) (V) 12.6 Iq (max) (mA) 9 Dynamic range (typ) (dB) 160 Reference type Int Auxiliary op amps 1 Full-scale output voltage (min) (±V) 4.8 Full-scale output voltage (max) (±V) 12.3 Conformity error (initial 5 decades) (max) (%) 1.5 Conformity error (initial 5 decades) (typ. over temp) (%/°C) 0.2 Operating temperature range (°C) -40 to 125 Rating Catalog
Input current range (min) (nA) 0.1 Input current range (max) (mA) 10 Offset voltage (input amplifiers) (max) (mV) 2000 Vs (±) (min) (V) 4.5 Vs (±) (max) (V) 12.6 Iq (max) (mA) 9 Dynamic range (typ) (dB) 160 Reference type Int Auxiliary op amps 1 Full-scale output voltage (min) (±V) 4.8 Full-scale output voltage (max) (±V) 12.3 Conformity error (initial 5 decades) (max) (%) 1.5 Conformity error (initial 5 decades) (typ. over temp) (%/°C) 0.2 Operating temperature range (°C) -40 to 125 Rating Catalog
VQFN (RGT) 16 9 mm² 3 x 3
  • Ultra-fast transient response to low current levels:
    • Settling time for 10‑nA to 100‑nA step: 220‑ns rising, 630‑ns falling (typ)
    • Settling time for 100‑nA to 1‑µA step: 80‑ns rising, 240‑ns falling (typ)
  • Wide dynamic current range: 100 pA to 10 mA (160 dB)
  • High signal bandwidth:
    • 6 MHz at 1 µA to 10 mA
    • 120 kHz at 1 nA
  • High-accuracy transfer function:
    • 0.2 % max log conformity error
  • Integrated reference current (1 µA) and reference voltages (2.5 V and 1.65 V) for accurate ratio calculation
  • Low reference drift: 20 ppm/°C (typ)
  • Additional auxiliary high-speed op amp for differential ADC drive, single-ended gain or filter blocks, and other peripheral functions
  • Single supply (4.5 V to 12.6 V) or dual supply (±2.25 V to ±6.3 V) operation
  • Low quiescent current: 9.5 mA
  • Specified temperature range: –40°C to +125°C
  • Small package: 3 mm × 3 mm VQFN
  • Ultra-fast transient response to low current levels:
    • Settling time for 10‑nA to 100‑nA step: 220‑ns rising, 630‑ns falling (typ)
    • Settling time for 100‑nA to 1‑µA step: 80‑ns rising, 240‑ns falling (typ)
  • Wide dynamic current range: 100 pA to 10 mA (160 dB)
  • High signal bandwidth:
    • 6 MHz at 1 µA to 10 mA
    • 120 kHz at 1 nA
  • High-accuracy transfer function:
    • 0.2 % max log conformity error
  • Integrated reference current (1 µA) and reference voltages (2.5 V and 1.65 V) for accurate ratio calculation
  • Low reference drift: 20 ppm/°C (typ)
  • Additional auxiliary high-speed op amp for differential ADC drive, single-ended gain or filter blocks, and other peripheral functions
  • Single supply (4.5 V to 12.6 V) or dual supply (±2.25 V to ±6.3 V) operation
  • Low quiescent current: 9.5 mA
  • Specified temperature range: –40°C to +125°C
  • Small package: 3 mm × 3 mm VQFN

The LOG200 is a wide-dynamic-range current-to-voltage amplifier specifically designed to optimize current measurements across 160 dB of dynamic range with unparalleled accuracy and speed for optical communications, medical diagnostics, and industrial process control measurements. The LOG200 features two logarithmic amplifiers followed by a high-accuracy differential amplifier that convert current signals into a voltage representing the log-compressed ratio of the two currents. The current inputs are designed to feature a high-speed response from one input, and a highly accurate reference signal on the other input, allowing for a unique combination of fast transient response and high logarithmic conformity.

The LOG200 ratio is internally set to 250 mV/decade of current-to-voltage conversion. The device integrates an uncommitted high-speed amplifier to allow the output to be configured for differential or filtered responses, with a fast settling time to drive successive approximation analog-to-digital converters (SAR ADCs). The LOG200 also features a separate reference current and reference voltage designed to configure the device for optimized input current and common-mode voltages.

The LOG200 can be powered in a single-supply (4.5 V to 12.6 V) or dual-supply (±2.25 V to ±6.3 V) configuration and is specified from –40°C to +125°C.

The LOG200 is a wide-dynamic-range current-to-voltage amplifier specifically designed to optimize current measurements across 160 dB of dynamic range with unparalleled accuracy and speed for optical communications, medical diagnostics, and industrial process control measurements. The LOG200 features two logarithmic amplifiers followed by a high-accuracy differential amplifier that convert current signals into a voltage representing the log-compressed ratio of the two currents. The current inputs are designed to feature a high-speed response from one input, and a highly accurate reference signal on the other input, allowing for a unique combination of fast transient response and high logarithmic conformity.

The LOG200 ratio is internally set to 250 mV/decade of current-to-voltage conversion. The device integrates an uncommitted high-speed amplifier to allow the output to be configured for differential or filtered responses, with a fast settling time to drive successive approximation analog-to-digital converters (SAR ADCs). The LOG200 also features a separate reference current and reference voltage designed to configure the device for optimized input current and common-mode voltages.

The LOG200 can be powered in a single-supply (4.5 V to 12.6 V) or dual-supply (±2.25 V to ±6.3 V) configuration and is specified from –40°C to +125°C.

Descargar Ver vídeo con transcripción Video

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 3
Tipo Título Fecha
* Data sheet LOG200 Precision, High-Speed Logarithmic Amplifier With Integrated Photodiode Bias datasheet PDF | HTML 14 ago 2023
EVM User's guide LOG200 Evaluation Module User's Guide (Rev. A) PDF | HTML 22 ene 2024
Certificate LOG200EVM EU Declaration of Conformity (DoC) 30 jun 2023

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

LOG200EVM — LOG200 evaluation module for high-speed precision logarithmic amplifier with photodiode bias

The LOG200 evaluation module (EVM) is a development platform for evaluating the LOG200, which is a precision, high-speed logarithmic amplifier with integrated photodiode bias and dark-current correction. LOG200 is optimized for current measurements across 160 dB of dynamic range with unparalleled (...)

Guía del usuario: PDF | HTML
Modelo de simulación

LOG200 PSpice Model

SBOMCF1.ZIP (97 KB) - PSpice Model
Modelo de simulación

LOG200 TINA-TI Reference Design

SBOMCF2.TSC (93 KB) - TINA-TI Reference Design
Modelo de simulación

LOG200 TINA-TI SPICE Model

SBOMCF0.ZIP (38 KB) - TINA-TI Spice Model
Herramienta de simulación

PSPICE-FOR-TI — PSpice® para herramienta de diseño y simulación de TI

PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
Herramienta de simulación

TINA-TI — Programa de simulación analógica basado en SPICE

TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
Guía del usuario: PDF
Paquete Pasadores Descargar
VQFN (RGT) 16 Ver opciones

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos