ホーム パワー・マネージメント AC/DC & DC/DC controllers (external FET)

-20℃ ~ 85℃、32V、1A、0.5MHz、オフライン PWM コントローラ

製品詳細

Vin (max) (V) 32 Operating temperature range (°C) -20 to 85 Control mode Peak current mode Topology Boost, Buck, Buck boost, Flyback, Forward Rating Catalog Duty cycle (max) (%) 95
Vin (max) (V) 32 Operating temperature range (°C) -20 to 85 Control mode Peak current mode Topology Boost, Buck, Buck boost, Flyback, Forward Rating Catalog Duty cycle (max) (%) 95
PDIP (N) 18 211.312 mm² 22.48 x 9.4 SOIC (DW) 18 118.965 mm² 11.55 x 10.3
  • All Control, Driving, Monitoring, and Protection Functions Included
  • Low-current, Off-line Start Circuit
  • Voltage Feed Forward or Current Mode Control
  • Guaranteed Duty Cycle Clamp
  • PWM Latch for Single Pulse per Period
  • Pulse-by-Pulse Current Limiting Plus Shutdown for Over-Current Fault
  • No Start-up or Shutdown Transients
  • Slow Turn-on Both Initially and After Fault Shutdown
  • Shutdown Upon Over- or Under-Voltage Sensing
  • Latch Off or Continuous Retry After Fault
  • PWM Output Switch Usable to 1A Peak Current
  • 1% Reference Accuracy
  • 500kHz Operation
  • 18 Pin DIL Package
  • All Control, Driving, Monitoring, and Protection Functions Included
  • Low-current, Off-line Start Circuit
  • Voltage Feed Forward or Current Mode Control
  • Guaranteed Duty Cycle Clamp
  • PWM Latch for Single Pulse per Period
  • Pulse-by-Pulse Current Limiting Plus Shutdown for Over-Current Fault
  • No Start-up or Shutdown Transients
  • Slow Turn-on Both Initially and After Fault Shutdown
  • Shutdown Upon Over- or Under-Voltage Sensing
  • Latch Off or Continuous Retry After Fault
  • PWM Output Switch Usable to 1A Peak Current
  • 1% Reference Accuracy
  • 500kHz Operation
  • 18 Pin DIL Package

The UC1841 family of PWM controllers has been designed to increase the level of versatility while retaining all of the performance features of the earlier UC1840 devices. While still optimized for highly-efficient boot-strapped primary-side operation in forward or flyback power converters, the UC1841 is equally adept in implementing both low and high voltage input DC to DC converters. Important performance features include a low-current starting circuit, linear feed-forward for constant volt-second operation, and compatibility with either voltage or current mode topologies.

In addition to start-up and normal regulating PWM functions, these devices include built in protection from over-voltage, under-voltage, and over-current fault conditions with the option for either latch-off or automatic restart.

While pin compatible with the UC1840 in all respects except that the polarity of the External Stop has been reversed, the UC1841 offers the following improvements:

1. Fault latch reset is accomplished with slow start discharge rather than recycling the input voltage to the chip.

2. The External Stop input can be used for a fault delay to resist shutdown from short duration transients.

3. The duty-cycle clamping function has been characterized and specified.

The UC1841 is characterized for -55°C to +125°C operation while the UC2841 and UC3841 are designed for -25°C to +85°C and 0°to +70°C, respectively.

The UC1841 family of PWM controllers has been designed to increase the level of versatility while retaining all of the performance features of the earlier UC1840 devices. While still optimized for highly-efficient boot-strapped primary-side operation in forward or flyback power converters, the UC1841 is equally adept in implementing both low and high voltage input DC to DC converters. Important performance features include a low-current starting circuit, linear feed-forward for constant volt-second operation, and compatibility with either voltage or current mode topologies.

In addition to start-up and normal regulating PWM functions, these devices include built in protection from over-voltage, under-voltage, and over-current fault conditions with the option for either latch-off or automatic restart.

While pin compatible with the UC1840 in all respects except that the polarity of the External Stop has been reversed, the UC1841 offers the following improvements:

1. Fault latch reset is accomplished with slow start discharge rather than recycling the input voltage to the chip.

2. The External Stop input can be used for a fault delay to resist shutdown from short duration transients.

3. The duty-cycle clamping function has been characterized and specified.

The UC1841 is characterized for -55°C to +125°C operation while the UC2841 and UC3841 are designed for -25°C to +85°C and 0°to +70°C, respectively.

ダウンロード 字幕付きのビデオを表示 ビデオ

お客様が関心を持ちそうな類似品

open-in-new 代替品と比較
比較対象デバイスと同等の機能で、ピン互換製品
UCC28C53 アクティブ 産業用、8.4V/7.6V UVLO 搭載、100% デューティ・サイクル対応、30V、低消費電力、電流モード PWM コントローラ Lower startup and supply current, better reference voltage accuracy and faster overcurrent protection

技術資料

star =TI が選定したこの製品の主要ドキュメント
結果が見つかりませんでした。検索条件をクリアしてから、再度検索を試してください。
3 をすべて表示
種類 タイトル 最新の英語版をダウンロード 日付
* データシート Programmable, Off-Line, PWM Controller データシート 1999年 9月 5日
セレクション・ガイド 電源 IC セレクション・ガイド 2018 (Rev. R 翻訳版) 英語版 (Rev.R) 2018年 9月 13日
アプリケーション・ノート DN-28 UC3840/UC3841/UC3851 PWM Controllers - Summary of Functions & Differences 1999年 9月 5日

設計と開発

その他のアイテムや必要なリソースを参照するには、以下のタイトルをクリックして詳細ページをご覧ください。

パッケージ ピン数 ダウンロード
PDIP (N) 18 オプションの表示
SOIC (DW) 18 オプションの表示

購入と品質

記載されている情報:
  • RoHS
  • REACH
  • デバイスのマーキング
  • リード端子の仕上げ / ボールの原材料
  • MSL 定格 / ピーク リフロー
  • MTBF/FIT 推定値
  • 材質成分
  • 認定試験結果
  • 継続的な信頼性モニタ試験結果
記載されている情報:
  • ファブの拠点
  • 組み立てを実施した拠点

サポートとトレーニング

TI E2E™ フォーラムでは、TI のエンジニアからの技術サポートを提供

コンテンツは、TI 投稿者やコミュニティ投稿者によって「現状のまま」提供されるもので、TI による仕様の追加を意図するものではありません。使用条件をご確認ください。

TI 製品の品質、パッケージ、ご注文に関するお問い合わせは、TI サポートをご覧ください。​​​​​​​​​​​​​​

ビデオ