SLUSFQ8B December 2024 – June 2025 BQ2969T
PRODMIX
Refer to the PDF data sheet for device specific package drawings
The scope plots below show the response of the device transitioning among the different states. Figure 8-4 shows the device detecting an overvoltage event and asserting the OUT pin to blow an external fuse after the overvoltage delay period. Figure 8-5 displays the device recovering from the overvoltage event when all cell voltages have fallen below the overvoltage threshold by the required hysteresis level, and the OUT pin deasserting. Figure 8-6 shows the device detecting an undervoltage condition and disabling the REG LDO output after the undervoltage delay period. Figure 8-7 then depicts the device recovering from the undervoltage condition and re-enabling the REG LDO when all cell voltages have risen above the undervoltage threshold by the required hysteresis level.
Figure 8-4 Overvoltage
Protection Triggering
Figure 8-6 Undervoltage
Detection to Disable the Regulator
Figure 8-5 Overvoltage
Protection Recovery
Figure 8-7 Undervoltage
Recovery to Re-enable the Regulator