SCHS463 May 2025 CD3268A , CD3269A
PRODUCTION DATA
| PARAMETER | DEFINITION | MIN | TYP | MAX | UNIT |
|---|---|---|---|---|---|
| Tone, Button, and Switch Timing | |||||
| tCAL | Calibration Tone Duration, (Figure 7-2) | 0.8 | 0.9 | 0.98 | ms |
| tACK | ACK Tone Duration, (Figure 7-2) | 5.0 | 5.5 | 6.0 | ms |
| tB | Button Tone Duration | 1.4 | 1.8 | 2.2 | ms |
| tDB | Button Debounce Time | 8.4 | 9.1 | 10 | ms |
| tM2T | Tone Send Delay after Tone Mode Enable, (Figure 7-2) | 4 | 6 | 8 | ms |
| tONA | Switch A Enable Time, (Figure 7-2) | 0.8 | 1.2 | 2 | ms |
| tOFFB | Switch B Disable Time, (Figure 7-2) | 0.7 | 1 | 2 | ms |
| tREG | Shunt Regulator Enable Time: time from MIC = 2.3V to MICPWR = 1.56V, (Figure 7-2) | 1 | 2.5 | 3.5 | ms |