SBOS764B December 2015 – December 2021 INA300-Q1
PRODUCTION DATA
Figure 5-1 DGS Package10-Pin VSSOPTop View| PIN | I/O | DESCRIPTION | |
|---|---|---|---|
| NO. | NAME | ||
| 1 | IN+ | Analog input | Connect to supply side of shunt resistor. |
| 2 | IN– | Analog input | Connect to load side of shunt resistor. |
| 3 | LIMIT | Analog input | Alert threshold limit input. See Section 7.3.2 for details on setting limit threshold. |
| 4 | ENABLE | Digital input | Enable or disable selection input |
| 5 | ALERT | Digital output | Overlimit alert, active-low, open-drain output. |
| 6 | LATCH | Digital input | Transparent or latch mode selection input. |
| 7 | DELAY | Digital input | Response time selection input. |
| 8 | GND | Analog | Ground |
| 9 | VS | Analog | Power supply, 2.7 V to 5.5 V. |
| 10 | HYS | Digital input | Hysteresis setting input. See Section 7.3.5 for hysteresis settings. |