SLLSER9D November   2016  – March 2023 ISO7710

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9. 6.9  Electrical Characteristics—5-V Supply
    10. 6.10 Supply Current Characteristics—5-V Supply
    11. 6.11 Electrical Characteristics—3.3-V Supply
    12. 6.12 Supply Current Characteristics—3.3-V Supply
    13. 6.13 Electrical Characteristics—2.5-V Supply 
    14. 6.14 Supply Current Characteristics—2.5-V Supply
    15. 6.15 Switching Characteristics—5-V Supply
    16. 6.16 Switching Characteristics—3.3-V Supply
    17. 6.17 Switching Characteristics—2.5-V Supply
    18. 6.18 Insulation Characteristics Curves
    19. 6.19 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Electromagnetic Compatibility (EMC) Considerations
    4. 8.4 Device Functional Modes
      1. 8.4.1 Device I/O Schematics
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
        1. 9.2.3.1 Insulation Lifetime
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 PCB Material
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • D|8
  • DW|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Revision History

Changes from Revision C (April 2020) to Revision D (March 2023)

  • Changed standard name from: "DIN V VDE V 0884-11:2017-01" to: "DIN EN IEC 60747-17 (VDE 0884-17)" throughout the documentGo
  • Removed references to standard IEC/EN/CSA 60950-1 throughout the documentGo
  • Removed standard revision and year references from all standard names throughout the document Go
  • Added Maximum impulse voltage (VIMP) specification per DIN EN IEC 60747-17 (VDE 0884-17)Go
  • Changed test conditions and values of Maximum surge isolation voltage (VIOSM) specification per DIN EN IEC 60747-17 (VDE 0884-17)Go
  • Clarified method b test conditions of Apparent charge (qPD)Go
  • Changed working voltage lifetime margin from: 87.5% to: 50%, minimum required insulation lifetime from: 37.5 years to: 30 years and insulation lifetime per TDDB from: 135 years to: 169 years in per DIN EN IEC 60747-17 (VDE 0884-17)Go
  • Changed Figure 9-5 per DIN EN IEC 60747-17 (VDE 0884-17)Go

Changes from Revision B (March 2017) to Revision C (April 2020)

  • Made editorial and cosmetic changes throughout the document Go
  • Changed From: "Isolation Barrier Life: >40 Years" To: " >100-year projected lifetime at 1500 VRMS working voltage" in Section 1 Go
  • Added "Up to 5000 VRMS isolation rating" in Section 1 Go
  • Added "Up to 12.8 kV surge capability" in Section 1 Go
  • Added "±8 kV IEC 61000-4-2 contact discharge protection across isolation barrier" in Section 1 Go
  • Added "Automotive version available: ISO7710-Q1" in Section 1 Go
  • Changed From: "VDE Reinforced Insulation per DIN V VDE V 0884-10 (VDE V 0884-10):2006-12" To: "VDE reinforced insulation per DIN VDE V 0884-11:2017-01" in Section 1 Go
  • Combined CSA, CQC, and TUV bullets into a single bullet with standard names in Section 1 Go
  • Deleted "VDE, UL, CSA, and TUV Certifications for DW-16 package complete; all other certifications planned" bullet in Section 1 Go
  • Updated Figure 3-1 to show two isolation capacitors in series instead of a single isolation capacitorGo
  •  Added "Contact discarge per IEC 61000-4-2" specification of 8000V  Go
  • Changed "Signaling rate" to "Data rate" and added table noteGo
  • Updated DW-16 package VIORM and VIOWM valuesGo
  • Added TDDB figure reference to VIOWM Go
  • Updated VIOSM, VIOTM, qpd test conditionsGo
  • Corrected ground symbols for "Input (Devices with F suffix)" in Section 8.4.1 Go
  • Fixed Figure 9-2 INPUT wire connectionGo
  • Added Section 9.2.3.1 sub-section under Section 9.2.3 sectionGo
  • Added 'How to use isolation to improve ESD, EFT, and Surge immunity in industrial systems' to Section 12.1 sectionGo

Changes from Revision A (December 2016) to Revision B (March 2017)

  • Added D-8 values for TUVGo
  • Changed the Electrostatic Discharge Caution statement Go

Changes from Revision * (November 2016) to Revision A (December 2016)

  • Changed Feature From: IEC 60950-1, IEC 60601-1 and IEC 61010-1 End Equipment Standards To: IEC 60950-1 and IEC 60601-1 End Equipment StandardsGo
  • Added Climatic categoryGo
  • Updated CSA column and changed DW package to (DW-16)Go
  • Changed tie TYP value from 1.5 to 1 in Switching Characteristics tables throughout the documentGo