SNVS700G December   2010  – October 2016 LM25066A

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Description (continued)
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Requirements: SMBus Communications
    7. 7.7 Switching Characteristics
    8. 7.8 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Current Limit
      2. 8.3.2 Circuit Breaker
      3. 8.3.3 Power Limit
      4. 8.3.4 Undervoltage Lockout (UVLO)
      5. 8.3.5 Overvoltage Lockout (OVLO)
      6. 8.3.6 Power Good
      7. 8.3.7 VDD Sub-Regulator
      8. 8.3.8 Remote Temperature Sensing
      9. 8.3.9 Damaged MOSFET Detection
    4. 8.4 Device Functional Modes
      1. 8.4.1 Power Up Sequence
      2. 8.4.2 Gate Control
      3. 8.4.3 Fault Timer and Restart
      4. 8.4.4 Shutdown Control
      5. 8.4.5 Enabling/Disabling and Resetting
    5. 8.5 Register Maps
      1. 8.5.1 PMBus Command Support
        1. 8.5.1.1 Standard PMBus™ Commands
          1. 8.5.1.1.1  OPERATION (01h)
          2. 8.5.1.1.2  CLEAR_FAULTS (03h)
          3. 8.5.1.1.3  CAPABILITY (19h)
          4. 8.5.1.1.4  VOUT_UV_WARN_LIMIT (43h)
          5. 8.5.1.1.5  OT_FAULT_LIMIT (4Fh)
          6. 8.5.1.1.6  OT_WARN_LIMIT (51h)
          7. 8.5.1.1.7  VIN_OV_WARN_LIMIT (57h)
          8. 8.5.1.1.8  VIN_UV_WARN_LIMIT (58h)
          9. 8.5.1.1.9  STATUS_BYTE (78h)
          10. 8.5.1.1.10 STATUS_WORD (79h)
          11. 8.5.1.1.11 STATUS_VOUT (7Ah)
          12. 8.5.1.1.12 STATUS_INPUT (7Ch)
          13. 8.5.1.1.13 STATUS_TEMPERATURE (7Dh)
          14. 8.5.1.1.14 STATUS_CML (7Eh)
          15. 8.5.1.1.15 STATUS_MFR_SPECIFIC (80h)
          16. 8.5.1.1.16 READ_VIN (88h)
          17. 8.5.1.1.17 READ_VOUT (8Bh)
          18. 8.5.1.1.18 READ_TEMPERATURE_1 (8Dh)
          19. 8.5.1.1.19 MFR_ID (99h)
          20. 8.5.1.1.20 MFR_MODEL (9Ah)
          21. 8.5.1.1.21 MFR_REVISION (9Bh)
        2. 8.5.1.2 Manufacturer Specific PMBus™ Commands
          1. 8.5.1.2.1  MFR_SPECIFIC_00: READ_VAUX (D0h)
          2. 8.5.1.2.2  MFR_SPECIFIC_01: MFR_READ_IIN (D1h)
          3. 8.5.1.2.3  MFR_SPECIFIC_02: MFR_READ_PIN (D2h)
          4. 8.5.1.2.4  MFR_SPECIFIC_03: MFR_IN_OC_WARN_LIMIT (D3h)
          5. 8.5.1.2.5  MFR_SPECIFIC_04: MFR_PIN_OP_WARN_LIMIT (D4h)
          6. 8.5.1.2.6  MFR_SPECIFIC_05: READ_PIN_PEAK (D5h)
          7. 8.5.1.2.7  MFR_SPECIFIC_06: CLEAR_PIN_PEAK (D6h)
          8. 8.5.1.2.8  MFR_SPECIFIC_07: GATE_MASK (D7h)
          9. 8.5.1.2.9  MFR_SPECIFIC_08: ALERT_MASK (D8h)
          10. 8.5.1.2.10 MFR_SPECIFIC_09: DEVICE_SETUP (D9h)
          11. 8.5.1.2.11 MFR_SPECIFIC_10: BLOCK_READ (DAh)
          12. 8.5.1.2.12 MFR_SPECIFIC_11: SAMPLES_FOR_AVG (DBh)
          13. 8.5.1.2.13 MFR_SPECIFIC_12: READ_AVG_VIN (DCh)
          14. 8.5.1.2.14 MFR_SPECIFIC_13: READ_AVG_VOUT (DDh)
          15. 8.5.1.2.15 MFR_SPECIFIC_14: READ_AVG_IIN (DEh)
          16. 8.5.1.2.16 MFR_SPECIFIC_15: READ_AVG_PIN (DFh)
          17. 8.5.1.2.17 MFR_SPECIFIC_16: BLACK_BOX_READ (E0h)
          18. 8.5.1.2.18 MFR_SPECIFIC_17: READ_DIAGNOSTIC_WORD (E1h)
          19. 8.5.1.2.19 MFR_SPECIFIC_18: AVG_BLOCK_READ (E2h)
        3. 8.5.1.3 Reading and Writing Telemetry Data and Warning Thresholds
        4. 8.5.1.4 Determining Telemetry Coefficients Empirically With Linear Fit
        5. 8.5.1.5 Writing Telemetry Data
        6. 8.5.1.6 PMBus™ Address Lines (ADR0, ADR1, ADR2)
        7. 8.5.1.7 SMBA Response
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 12-V, 45-A PMBus Hotswap Design
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1  Select RSNS and CL Setting
          2. 9.2.1.2.2  Selecting the Hotswap FETs
          3. 9.2.1.2.3  Select Power Limit
          4. 9.2.1.2.4  Set Fault Timer
          5. 9.2.1.2.5  Check MOSFET SOA
          6. 9.2.1.2.6  Switching to dV/dt based Start-up
          7. 9.2.1.2.7  Choosing the VOUT Slew Rate
          8. 9.2.1.2.8  Select Power Limit and Fault Timer
          9. 9.2.1.2.9  Set Undervoltage and Overvoltage Threshold
            1. 9.2.1.2.9.1 Option A
            2. 9.2.1.2.9.2 Option B
            3. 9.2.1.2.9.3 Option C
            4. 9.2.1.2.9.4 Option D
          10. 9.2.1.2.10 Power Good Pin
          11. 9.2.1.2.11 Input and Output Protection
          12. 9.2.1.2.12 Final Schematic and Component Values
      2. 9.2.2 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Device Support
      1. 12.1.1 Development Support
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Community Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Description (continued)

The LM25066A monitoring block computes both the real-time and average values of subsystem operating parameters (VIN, IIN, PIN, VOUT) as well as the peak power. Accurate power averaging is accomplished by averaging the product of the input voltage and current. A black box (Telemetry/Fault Snapshot) function captures and stores telemetry data and device status in the event of a warning or a fault.