SLOS074A October   1983  – December 2024 RC4559

PRODUCTION DATA  

  1.   1
  2. 1Features
  3. 2Applications
  4. 3Description
  5. 4Specifications
    1. 4.1 Absolute Maximum Ratings
    2. 4.2 Electrical Characteristics
    3. 4.3 Matching Characteristics
    4. 4.4 Operating Characteristics
  6. 5Device and Documentation Support
    1. 5.1 Receiving Notification of Documentation Updates
    2. 5.2 Support Resources
    3. 5.3 Trademarks
    4. 5.4 Electrostatic Discharge Caution
    5. 5.5 Glossary
  7. 6Revision History
  8. 7Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • D|8
  • P|8
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Supply voltage VCC+ (see (1)) 18 V
Supply voltage VCC− (see (1)) −18 V
Differential input voltage (see (2)) ±30 V
Input voltage (any input, see (1) and 3) ±15 V
Short-circuit output current (see (4)) 125 mA
Continuous total dissipation 500 mW
Operating free-air temperature range 0 70 °C
Storage temperature range −65 125 °C
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds 260 °C
All voltage values, unless otherwise noted, are with respect to the zero reference level (ground) of the supply voltages where the zero reference level is the midpoint between VCC+ and VCC−.
Differential voltages are at the noninverting input terminal with respect to the inverting input terminal.
The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts, whichever is less.
Temperature or supply voltages must be limited to ensure that the dissipation rating is not exceeded.