over operating free-air temperature range (unless otherwise noted)
(1)
|
MIN |
MAX |
UNIT |
| VCC
|
Supply voltage range |
|
–0.5 |
7 |
V |
| VI(2) |
Input voltage range |
|
‐0.5 |
VCC + 0.5 |
V |
| VO(2) |
Output voltage range |
|
‐0.5 |
VCC + 0.5 |
V |
| IIK |
Input clamp current |
(VI < 0 or VI >
VCC) |
|
±20 |
mA |
| IOK
|
Output clamp current |
(VO < 0 or VO >
VCC) |
|
±20 |
mA |
| IO
|
Continuous output current |
(VO = 0 or VCC) |
|
±50 |
mA |
|
Continuous current through VCC or GND |
|
|
±200 |
mA |
| Tstg
|
Storage temperature range |
|
–65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings
may cause permanent device damage. Absolute Maximum Ratings do not imply
functional operation of the device at these or any other conditions beyond those
listed under Recommended Operating Conditions. If used outside the
Recommended Operating Conditions but within the Absolute Maximum
Ratings, the device may not be fully functional, and this may affect
device reliability, functionality, performance, and shorten the device lifetime.